Overcurrent Protection for Gyrotrons in EAST ECRH System

机译:EasT ECRH系统中陀螺仪的过流保护

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In this paper, an overcurrent protection system is designed to ensure thesafety of the gyrotrons in the EAST ECRH system. Two overcurrent protectionsystems were established, a fast one and a slow one. The fast one uses thecurrent transformers as the current sensors. The models of the currenttransformers and the superconducting magnet were built to analyze the effect ofthe environmental magnetic field on the current transformers using FI method.The analysis results show that the magnetic induction at the position near thecurrent transformers must less than 0.002 T, i.e., the current transformersshould be placed at a distance greater than 2.2 meters from the magnet centerto ensure its normal work. The slow one uses the shunt to monitor the currents.An anti-fuse FPGA and a timer is used to realize the signal processing in thefast protection circuit and the slow protection circuit respectively. Theresponse time of the fast protection circuit is less than 100 ns, and theresponse time of the slow protection circuit is less than 31 {\mu}s.
机译:本文设计了一种过流保护系统,以确保EAST ECRH系统中回旋管的安全。建立了两个过电流保护系统,一个快速保护系统和一个慢速保护系统。快速的使用电流互感器作为电流传感器。建立了电流互感器和超导磁体的模型,运用FI方法分析了环境磁场对电流互感器的影响。分析结果表明,电流互感器附近的磁感应强度必须小于0.002 T。电流互感器应放置在距磁铁中心2.2米以上的距离处,以确保其正常工作。慢速保护器使用分流器监视电流。反熔丝FPGA和定时器分别用于快速保护电路和慢速保护电路中的信号处理。快速保护电路的响应时间小于100ns,慢速保护电路的响应时间小于31μs。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号