Construction and Test of New Precision Drift-Tube Chambers for the ATLAS Muon Spectrometer

机译:aTLas新型精密漂移管腔的结构与试验   muon光谱仪

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

ATLAS muon detector upgrades aim for increased acceptance for muon triggeringand precision tracking and for improved rate capability of the muon chambers inthe high-background regions of the detector with increasing LHC luminosity. Thesmall-diameter Muon Drift Tube (sMDT) chambers have been developed for thesepurposes. With half of the drift-tube diameter of the MDT chambers andotherwise unchanged operating parameters, sMDT chambers share the advantages ofthe MDTs, but have an order of magnitude higher rate capability and can beinstalled in detector regions where MDT chambers do not fit in. The chamberassembly methods have been optimized for mass production, minimizingconstruction time and personnel. Sense wire positioning accuracies of 5 ?miconshave been achieved in serial production for large-size chambers comprisingseveral hundred drift tubes. The construction of new sMDT chambers forinstallation in the 2016/17 winter shutdown of the LHC and the design of sMDTchambers in combination with new RPC trigger chambers for replacement of theinner layer of the barrel muon spectrometer are in progress.
机译:ATLAS介子探测器的升级旨在提高对μ子触发和精确跟踪的接受度,并随着LHC发光度的提高,提高探测器高背景区域中的介子腔的速率能力。小直径的Muon漂移管(sMDT)腔室已针对这些目的而开发。 sMDT腔室具有MDT腔室的漂移管直径的一半,而工作参数不变,则sMDT腔室具有MDT的优势,但速率能力高一个数量级,可以安装在不适合MDT腔室的检测器区域。已针对批量生产优化了方法,从而最大程度地减少了施工时间和人员。批量生产包括几百个漂移管的大型腔室时,已经实现了5 µicon的传感线定位精度。 LHC的2016/17冬季停工时将安装新的sMDT腔室,并正在设计与新的RPC触发腔室相结合的sMDTchambers室,以替换桶式μon光谱仪的内层。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号