首页> 外文OA文献 >Dry demagnetization cryostat for sub-millikelvin helium experiments: refrigeration and thermometry
【2h】

Dry demagnetization cryostat for sub-millikelvin helium experiments: refrigeration and thermometry

机译:用于亚毫克尔氦实验的干式退磁低温恒温器:   制冷和测温

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We demonstrate successful "dry" refrigeration of quantum fluids down to$T=0.16$\,mK by using copper nuclear demagnetization stage that is pre-cooledby a pulse-tube-based dilution refrigerator. This type of refrigerationdelivers a flexible and simple sub-mK solution to a variety of needs includingexperiments with superfluid $^3$He. Our central design principle was toeliminate relative vibrations between the high-field magnet and the nuclearrefrigeration stage, which resulted in the minimum heat leak of $Q=4.4$\,nWobtained in field of 35\,mT. For thermometry, we employed a quartz tuning fork immersed into liquid$^3$He. We show that the fork oscillator can be considered as self-calibratingin superfluid $^3$He at the crossover point from hydrodynamic into ballisticquasiparticle regime.
机译:我们演示了通过使用铜核退磁级(通过基于脉冲管的稀释制冷机进行预冷却),成功地将量子流体“干燥”致冷至$ T = 0.16 $,mK。这种制冷方式可为各种需求提供灵活,简单的sub-mK解决方案,包括使用超流体$ ^ 3 $ He进行的实验。我们的中心设计原理是消除高磁场磁体与核制冷级之间的相对振动,从而在35 \ mT的磁场中获得的最小热泄漏为$ Q = 4.4 $ \ n。为了进行测温,我们使用了浸入液体$ ^ 3 $ He中的石英音叉。我们表明,在流体动力学到弹道准粒子状态的交叉点,叉形振荡器可以被视为超流体$ ^ 3 $ He的自校准。