首页> 外文OA文献 >Accurate Measurements of the Intrinsic Surface Impedance of Thin YBCO Films Using a Modified Two-tone Resonator Method
【2h】

Accurate Measurements of the Intrinsic Surface Impedance of Thin YBCO Films Using a Modified Two-tone Resonator Method

机译:精确测量薄YBCO的本征表面阻抗   使用改进的双音谐振器方法的薄膜

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We propose a modified two-tone method that could be used for sensitivemeasurements of the intrinsic microwave surface impedance (Zs) of thinsuperconductor films and the tand of a low-loss dielectric. An open-gapresonator scheme is used to measure the penetration depth of thinsuperconductor films and extract the intrinsic Zs of the superconductor filmsfrom its measured effective surface resistance and penetration depth. We use avery small gap of 10 um between the top plate and the rest parts of theresonator. The loss tangent of rutile in the low 10^-7 range and the dielectricconstant as high as ~110 are observed at temperatures below 10 K at ~15.2 GHz,which enable to measure the Rs of the 10 mm-in-diameter YBCO films as low as\~100 micro-ohm at the same frequency (f). The discrepancy between theeffective surface resistance at ~15.2 GHz and that at ~8.5 GHz scaled to ~15.2GHz appears less than 6 % when the relations of Rs ~ f^2 and loss tangent ~ fare used. We describe usefulness of our measurement method for measuring theintrinsic microwave properties of various superconductor samples.
机译:我们提出了一种改进的两音调方法,该方法可用于灵敏测量超导薄膜的本征微波表面阻抗(Zs)和低损耗电介质的双绞线。使用开放式谐振器方案测量超导体薄膜的穿透深度,并从其测量的有效表面电阻和穿透深度中提取超导体薄膜的本征Zs。我们在顶板和谐振器的其余部分之间使用平均10 um的小间隙。在低于15.2 GHz的10 K温度下,观察到金红石的损耗角正切在低10 ^ -7范围内,介电常数高达〜110,这可以测量10 mm直径YBCO膜的Rs为在相同频率下(f)低至100微欧。当使用Rs〜f ^ 2与损耗正切〜费率的关系时,在〜15.2 GHz处的有效表面电阻与在〜8.5 GHz时缩放至〜15.2 GHz的有效表面电阻之间的差异小于6%。我们描述了我们的测量方法对测量各种超导体样品的固有微波特性的有用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号