Erythromycin, a macrolide antibiotic used mainly against gram-positive bacteria has been in clinical use since 1952 (1). Previous pharmacokinetic data published on this antibiotic have been derived predominantly from microbiological assay techniques. However, these techniques are relatively imprecise as well as being non-specific and extremely tedious to perform. A novel high performance liquid chromatographic analysis of erythromycin in human serum and urine using U.V. detection at 200 nm and/or electrochemical detection using both an amperometric and a coulometric electrochemical detector is presented. The method involves a solid phase extraction procedure followed by a simple phase separation step and chromatography on a reverse phase column. In order to select the optimum U.V. detector for this analysis, five "state of the art" detectors were compared in terms of their signal-to-noise ratios at U.V. wavelengths between 200 and 210 nm. A known metabolite des-N-methylerythromycin is readily detectable using U.V. detection, whilst another metabolite/degradation product anhydroerythromycin is not seen using U.V. detection but is readily observable using an electrochemical detector. The method has a limit of sensitivity of 0.25 μg/mL and 1.00 μg/mL in serum and urine respectively (U.V. detection) and is sufficiently sensitive to monitor serum and urine concentrations of erythromycin in man after administration of a single 500 mg erythromycin stearate tablet.
机译:红霉素,一种主要用于革兰氏阳性菌的大环内酯类抗生素,自1952年以来就已投入临床使用(1)。有关该抗生素的先前药代动力学数据主要来自微生物测定技术。但是,这些技术相对不精确,并且非特定性且执行起来非常繁琐。使用U.V.的新型高效液相色谱法分析人血清和尿液中的红霉素提出了在200 nm处进行检测和/或使用安培和库仑电化学检测器进行电化学检测。该方法涉及固相萃取程序,然后进行简单的相分离步骤并在反相柱上进行色谱分离。为了选择最佳的U.V.为了进行这种分析,我们比较了五个“最先进”的检测器,它们在U.V时的信噪比。波长在200至210 nm之间。已知的代谢物des-N-甲基红霉素可以通过U.V.检测,而使用U.V看不到另一种代谢产物/降解产物脱水红霉素。检测,但可以使用电化学检测器轻松观察到。该方法在血清和尿液中的灵敏度极限分别为0.25μg/ mL和1.00μg/ mL(紫外线检测),并且足够敏感,可以在单剂500 mg硬脂酸红霉素片给药后监测人体内红霉素的血清和尿液浓度。 。

著录项

  • 作者

    Stubbs Christopher;

  • 作者单位
  • 年度 2013
  • 总页数
  • 原文格式 PDF
  • 正文语种 English
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号