首页> 外文OA文献 >Development and validation of a novel non-contact monitor of nocturnal respiration for identifying sleep-disordered breathing in patients with heart failure
【2h】

Development and validation of a novel non-contact monitor of nocturnal respiration for identifying sleep-disordered breathing in patients with heart failure

机译:开发和验证新型非接触式夜间呼吸监测器,用于识别心力衰竭患者的睡眠呼吸紊乱

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Aims At least 50% of patients with heart failure (HF) may have sleep-disordered breathing (SDB). Overnight in-hospital polysomnography (PSG) is considered the gold standard for diagnosis, but a lack of access to such testing contributes to under-diagnosis of SDB. Therefore, there is a need for simple and reliable validated methods to aid diagnosis in patients with HF. The aim of this study was to investigate the accuracy of a non-contact type IV screening device, SleepMinderTM (SM), compared with in-hospital PSG for detecting SDB in patients with HF. Methods and results The study included 75 adult patients with systolic HF and suspected SDB who underwent simultaneous PSG and SM recordings. An algorithm was developed from the SM signals, using digital signal processing and pattern recognition techniques to calculate the SM apnoea-hypopnoea index (AHI). This was then compared with expert-scored PSGAHI. The SM algorithm had 70% sensitivity and 89% specificity for identifying patients with clinically significant SDB (AHI ≥ 15/h). At this threshold, it had a positive likelihood ratio of 6.3 and a negative likelihood ratio of 0.16. The overall accuracy of the SMAHI algorithm was 85.8% as shown by the area under a receiver operator characteristic curve. The mean AHI with SM was 3.8/h (95% confidence interval 0.5–7.1) lower than that with PSG. Conclusions The accuracy of the non-contact type IV screening device SM is good for clinically significant SDB in patients with systolic HF and could be considered as a simple first step in the diagnostic pathway.
机译:目的至少50%的心力衰竭(HF)患者可能患有睡眠呼吸障碍(SDB)。过夜的医院多导睡眠图(PSG)被认为是诊断的金标准,但缺乏此类检查的机会会导致SDB的诊断不足。因此,需要简单可靠的经过验证的方法来辅助HF患者的诊断。这项研究的目的是研究非接触式IV型筛查设备SleepMinderTM(SM)与院内PSG相比在HF患者中检测SDB的准确性。方法和结果该研究包括75例同时发生PSG和SM记录的成年收缩期HF和疑似SDB患者。利用数字信号处理和模式识别技术,从SM信号中开发出一种算法,以计算SM呼吸暂停-呼吸不足指数(AHI)。然后将其与专家评分的PSGAHI进行比较。 SM算法对鉴定具有临床意义的SDB(AHI≥15 / h)的患者具有70%的敏感性和89%的特异性。在此阈值下,它的正似然比为6.3,负似然比为0.16。 SMAHI算法的整体精度为85.8%,如接收方操作员特征曲线下的面积所示。 SM的平均AHI比PSG的平均3.8 / h(95%置信区间0.5–7.1)低。结论非接触式IV型筛查设备SM的准确性对收缩期HF患者具有临床意义的SDB良好,可被认为是诊断途径中的简单第一步。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号