A novel approach to identify non-palpable breast lesions combining fluorescent liposomes and magnetic resonance-guided high intensity focused ultrasound-triggered release

机译:一种结合荧光脂质体和磁共振引导的高强度聚焦超声触发释放来识别不可触及的乳腺病变的新方法

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The combination of fluorescein-containing liposomes (FCL) and magnetic resonance-guided high intensity focused ultrasound (MR-HIFU)-triggered release is a promising approach for lesion demarcation and more efficient removal of non-palpable breast lesions. Exposure of FCL to ablation temperatures (60 degrees C) using MR-HIFU would result in palpable, stained tumors, which are more easy to identify during surgical resection. In this study, proof-of-concept concerning fluorescent FCL for MR-HIFU-triggered release and tumor demarcation of non-palpable breast lesions is presented. Ex vivo experiments in human blood and porcine muscle tissue showed increased label release from the liposomes, clear fluorescence enhancement and diffusion of the released compound after heating to 60 degrees C. Next, fluorescein release of FCL was observed after MR-HIFU-mediated mild hyperthermia (42 degrees C) and ablation temperature (60 degrees C) for a short period (30 s), which is in line with the clinically relevant MR-HIFU treatment parameters. These results indicate the potential of the FCL as a tool to improve tumor demarcation in patients by MR-HIFU-triggered release. Therefore, this method may offer a new tool for efficient surgical resection of non-palpable breast tumor lesions by enabling proper discrimination between tumor tissue and adjacent healthy tissue. (C) 2011 Elsevier B.V. All rights reserved.
机译:含荧光素脂质体(FCL)和磁共振引导的高强度聚焦超声(MR-HIFU)触发释放的组合是一种有希望的病变分界方法,可以更有效地去除不可触及的乳腺病变。使用MR-HIFU将FCL暴露在消融温度(60摄氏度)下会导致可触及的,染色的肿瘤,在手术切除过程中更容易识别。在这项研究中,提出了关于荧光FCL用于MR-HIFU触发的释放和不可触及的乳腺病变的肿瘤分界的概念证明。在人体血液和猪肌肉组织中的离体实验显示,加热至60摄氏度后,脂质体中的标记释放增加,释放的化合物具有明显的荧光增强和扩散。接下来,在MR-HIFU介导的轻度高热后观察到FCL的荧光素释放(42摄氏度)和短时(30 s)的消融温度(60摄氏度),符合临床相关的MR-HIFU治疗参数。这些结果表明,FCL作为通过MR-HIFU触发释放改善患者肿瘤分界的工具的潜力。因此,该方法可以通过对肿瘤组织和相邻健康组织进行适当的区分,为有效手术切除不可触及的乳腺肿瘤病变提供一种新的工具。 (C)2011 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号