首页> 外文OA文献 >Absorption of CO2 and H2S in aqueous alkanolamine solutions using a fixed-bed reactor with cocurrent downflow operation in the pulsing flow regime = Absorption von CO2 und H2S in wäßrigen alkanolamin-lösungen in einem Festbettreaktor bei abwärtsfließendem Gleichstrombetrieb und pulsierendem Arbeiten
【2h】

Absorption of CO2 and H2S in aqueous alkanolamine solutions using a fixed-bed reactor with cocurrent downflow operation in the pulsing flow regime = Absorption von CO2 und H2S in wäßrigen alkanolamin-lösungen in einem Festbettreaktor bei abwärtsfließendem Gleichstrombetrieb und pulsierendem Arbeiten

机译:使用固定床反应器在脉冲流态下并流向下流动,在链烷醇胺水溶液中吸收CO2和H2S =在固定床反应器中使用下行流式直流操作和脉冲作用,吸收链烷醇胺水溶液中的CO2和H2S

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Absorption rates of H2S and CO2 in several aqueous alkanolamines in a cocurrent downflow fixed-bed reactor operated in the pulse flow regime have been measured in order to obtain information on the potential selectivity and on the mass transfer parameters. From these experiments it can be concluded that this type of reactor seems to be very suitable for the selective removal of H2S from acid gases. It was not possible to derive correlations which are always valid for the calculation of the mass transfer parameters in laboratory-scale contactors. The results of the present study in combination with the data published in the literature were correlated with only one unknown parameter in which the influence of the physical properties of the system and the shape and material of the packing were combined. This parameter has to be determined empirically. Small amounts of acid gases in aqueous alkanolamine solutions have a pronounced effect on the properties, such as the foaming behaviour, of the liquid phase. The pressure drops measured in the cocurrently operated fixed-bed reactor were affected substantially by small amounts of acid gases present in the aqueous alkanolamine solutions and up to now this effect could not be explained satisfactorily. For the design of contactors for industrial purposes, detailed scale-up rules are required. In the present study this aspect is not investigated.
机译:为了获得有关潜在选择性和传质参数的信息,已测量了在脉冲流方式下运行的并流下流固定床反应器中,几种链烷醇胺水溶液中H2S和CO2的吸收速率。从这些实验可以得出结论,这种类型的反应器似乎非常适合从酸性气体中选择性去除H2S。不可能得出对于实验室规模接触器中传质参数的计算始终有效的相关性。本研究的结果与文献中发表的数据相结合,仅与一个未知参数相关,该参数结合了系统物理性质的影响以及填料的形状和材料。该参数必须凭经验确定。链烷醇胺水溶液中的少量酸性气体对液相的性能(例如起泡行为)有显着影响。在并流操作的固定床反应器中测得的压降基本上受到链烷醇胺水溶液中存在的少量酸性气体的影响,到目前为止,这种效果尚不能令人满意地解释。对于工业用途的接触器设计,需要详细的放大规则。在本研究中,未对此方面进行研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号