摘要

textabstractObjectives: A non-invasive method to measure the bladder pressure in males using a condom catheter has been developed. The measurement technique, its validation and limitations, a diagnostic nomogram to non-invasively diagnose bladder outlet obstruction (BOO), and results of large-scale application are discussed. Methods: Modified incontinence condoms are attached to the penis. During voiding the flow of urine is mechanically interrupted. The subsequent maximum pressure in the condom reflects the isovolumetric bladder pressure. The method was validated in a group of 46 patients with lower urinary tract symptoms who were simultaneously studied invasively and non-invasively. Subsequently it was applied in a non-invasive epidemiological study in 1020 healthy males. Results: The reproducibility of the measured isovolumetric bladder pressure is comparable to that of conventional pressure-flow parameters. The measured pressure can be used to diagnose bladder outlet obstruction with a diagnostic accuracy (Area Under receiver operator characteristic curve) of 0.98, which compares most favorably with the area under the curve of 0.79 of Qmax in the same population. During condom catheter measurements, both the involuntary interruption of voiding and the forced diuresis increase post-void residual volume. This increase does not affect the accuracy of the pressure measurements. Conclusions: We conclude that in males bladder pressure can successfully be measured non-invasively using the condom catheter method. By combining the measured volumetric bladder pressure with a separately measured free flow rate, BOO can non-invasively and accurately be diagnosed.
机译:目的:已开发出一种使用避孕套导管测量男性膀胱压力的非侵入性方法。讨论了测量技术,其验证和局限性,用于非侵入性诊断膀胱出口梗阻(BOO)的诊断列线图以及大规模应用的结果。方法:将改良的失禁避孕套附着在阴茎上。在排尿期间,尿液流动被机械中断。避孕套中随后的最大压力反映了等容膀胱压力。该方法在一组46例下尿路症状患者中得到了验证,这些患者同时进行了有创和无创研究。随后,它被用于1020名健康男性的非侵入性流行病学研究中。结果:测得的等体积膀胱压力的重现性与常规压力-流量参数相当。测得的压力可用于诊断膀胱出口阻塞,诊断准确度(接受者操作者特征曲线下的面积)为0.98,与同一人群中Qmax的曲线下面积0.79最相称。在避孕套导管测量期间,排尿的非自愿中断和强制利尿都会增加排尿后的残留量。这种增加不会影响压力测量的准确性。结论:我们得出的结论是,使用避孕套导管方法可以成功地无创地测量男性膀胱压力。通过将测得的膀胱容积压力与单独测得的自由流速相结合,可以无创且准确地诊断BOO。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号