Subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the IOC Medical Commission.

机译:运动员的皮下脂肪模式:选择合适的部位并标准化新型超声测量技术:在国际奥委会医学委员会的主持下,有关身体成分,健康和表现的特设工作组。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: Precise and accurate field methods for body composition analyses in athletes are needed urgently. Aim Standardisation of a novel ultrasound (US) technique for accurate and reliable measurement of subcutaneous adipose tissue (SAT). Methods: Three observers captured US images of uncompressed SAT in 12 athletes and applied a semiautomatic evaluation algorithm for multiple SAT measurements. Results: Eight new sites are recommended: upper abdomen, lower abdomen, erector spinae, distal triceps, brachioradialis, lateral thigh, front thigh, medial calf. Obtainable accuracy was 0.2 mm (18 MHz probe; speed of sound: 1450 m/s). Reliability of SAT thickness sums (N=36): R2=0.998, SEE=0.55 mm, ICC (95% CI) 0.998 (0.994 to 0.999); observer differences from their mean: 95% of the SAT thickness sums were within ±1 mm (sums of SAT thicknesses ranged from 10 to 50 mm). Embedded fibrous tissues were also measured. Conclusions: A minimum of eight sites is suggested to accommodate inter-individual differences in SAT patterning. All sites overlie muscle with a clearly visible fascia, which eases the acquisition of clear images and the marking of these sites takes only a few minutes. This US method reaches the fundamental accuracy and precision limits for SAT measurements given by tissue plasticity and furrowed borders, provided the measurers are trained appropriately.
机译:背景:迫切需要用于运动员身体成分分析的精确,准确的现场方法。旨在标准化和可靠测量皮下脂肪组织(SAT)的新型超声(US)技术。方法:三名观察员在12名运动员中捕获了未压缩SAT的美国图像,并将半自动评估算法应用于多次SAT测量。结果:推荐八个新部位:上腹部,下腹部,竖脊肌,肱三头肌远端,肱bra肌,大腿外侧,大腿前侧,小腿内侧。可获得的精度为0.2毫米(18 MHz探头;声速:1450 m / s)。 SAT厚度总和的可靠性(N = 36):R2 = 0.998,SEE = 0.55 mm,ICC(95%CI)0.998(0.994至0.999);观察者与平均值的差异:SAT厚度总和的95%在±1 mm以内(SAT厚度总和在10至50 mm范围内)。还测量了包埋的纤维组织。结论:建议最少八个位点以适应SAT模式的个体差异。所有部位均以清晰可见的筋膜覆盖在肌肉上,从而易于获得清晰的图像,并且这些部位的标记仅需几分钟。如果对测量员进行了适当的培训,则这种US方法达到了由组织可塑性和弯曲的边界所给的SAT测量的基本精度和精确度极限。