首页> 外文OA文献 >Comparison of 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine-enhanced MRI in 471 patients with known or suspected renal lesions: Results of a multicenter, single-blind, interindividual, randomized clinical phase III trial
【2h】

Comparison of 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine-enhanced MRI in 471 patients with known or suspected renal lesions: Results of a multicenter, single-blind, interindividual, randomized clinical phase III trial

机译:471例已知或疑似肾脏病变的患者中1.0 M加度丁醇和0.5 M加度戊二酸二聚亮氨酸增强MRI的比较:一项多中心,单盲,个体间,随机临床III期试验的结果

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

textabstractThe purpose of this phase III clinical trial was to compare two different extracellular contrast agents, 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine, for magnetic resonance imaging (MRI) in patients with known or suspected focal renal lesions. Using a multicenter, single-blind, interindividual, randomized study design, both contrast agents were compared in a total of 471 patients regarding their diagnostic accuracy, sensitivity, and specificity to correctly classify focal lesions of the kidney. To test for noninferiority the diagnostic accuracy rates for both contrast agents were compared with CT results based on a blinded reading. The average diagnostic accuracy across the three blinded readers ('average reader') was 83.7% for gadobutrol and 87.3% for gadopentate dimeglumine. The increase in accuracy from precontrast to combined precontrast and postcontrast MRI was 8.0% for gadobutrol and 6.9% for gadopentate dimeglumine. Sensitivity of the average reader was 85.2% for gadobutrol and 88.7% for gadopentate dimeglumine. Specificity of the average reader was 82.1% for gadobutrol and 86.1% for gadopentate dimeglumine. In conclusion, this study documents evidence for the noninferiority of a single i.v. bolus injection of 1.0 M gadobutrol compared with 0.5 M gadopentate dimeglumine in the diagnostic assessment of renal lesions with CE-MRI.
机译:这项III期临床试验的目的是比较两种不同的细胞外造影剂,即1.0 M加多布特罗和0.5 M加多戊酸二聚亮氨酸,用于已知或疑似局灶性肾病患者的磁共振成像(MRI)。使用多中心,单盲,个体间,随机研究设计,在总共471名患者中比较了两种造影剂的诊断准确性,敏感性和正确分类肾脏局灶性病变的特异性。为了测试非劣效性,将两种造影剂的诊断准确率与基于盲法读数的CT结果进行了比较。三种不明阅读器(“平均阅读器”)的平均诊断准确度对于gadobutrol为83.7%,对gadopentate dimeglumine为87.3%。加多布特罗从造影前到联合造影前和造影后MRI的准确度提高了8.0%,而戊二酸二聚谷氨酸则提高了6.9%。加多布特罗的平均阅读器灵敏度为85.2%,加多巴酸二葡甲胺的灵敏度为88.7%。普通阅读者对gadobutrol的特异性为82.1%,对gadopentate dimeglumine的特异性为86.1%。总之,这项研究记录了单个i.v.推注1.0 M加多巴特罗与0.5 M加多巴酸二聚丁二胺进行CE-MRI诊断肾损害的评估。

相似文献

  • 外文文献
  • 中文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号