We present here the experimental setup and standardization of a newly acquired stable isotope ratio mass-spectrometer (Isoprime 100, Isoprime(A (R)) UK) coupled with elemental analyzer (Pyrocube, Elementar(A (R))-Germany) in a continuous flow mode, for the measurements of C, N and S isotopes in a variety of natural as well as synthetic organics and sulfur containing solid samples. We have calibrated our instrument using a suite of certified international standards supplied by International Atomic Energy Agency Vienna and cross-checked against several in-house laboratory standards used by other institutions of international repute. A synthetic organic compound Sulfanilamide was continuously used along with international standards to develop an in-house internal laboratory standard for the accurate and precise isotopic measurements. Important components contributing to the overall uncertainty of the isotopic measurements such as blank contributions, amount effect and response of mass-spectrometric current against thermal conductivity detector were performed using several aliquots of epsilon-Amino-n-caproic acid and sulfanilamide (in-house) standards. Both short and long term variabilities in the measure isotopic data were assessed using our in-house laboratory standard Sulfanilamide. Overall estimated uncertainties of C, N and S isotopic measurements are better than 0.2, 0.2 and 0.3 aEuro degrees, respectively; which are well within the recommended limits of aforementioned isotopic data.
机译:我们在这里介绍了新获得的稳定同位素比率质谱仪(Isoprime 100,Isoprime(A(R))UK)与元素分析仪(Pyrocube,Elementar(A(R))-Germany)的实验设置和标准化。连续流动模式,用于测量各种天然以及合成有机物和含硫固体样品中的C,N和S同位素。我们已经使用维也纳国际原子能机构提供的一组认证国际标准对我们的仪器进行了校准,并与其他国际声誉机构使用的几种内部实验室标准进行了交叉核对。合成的有机化合物磺胺一直与国际标准一起使用,以开发内部内部实验室标准,以进行准确而精确的同位素测量。使用ε-氨基-正己酸和磺胺(内部)的等分试样进行了导致同位素测量总体不确定性的重要成分,例如空白贡献,量效应和质谱电流对热导检测器的响应标准。测量同位素数据的短期和长期变化都使用我们内部实验室标准的磺胺酰胺进行了评估。 C,N和S同位素测量的总体估计不确定度分别优于0.2、0.2和0.3 aEuro度;完全在上述同位素数据的建议范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号