首页> 外文OA文献 >A combination of motion-compensated cone-beam computed tomography image reconstruction and electrical impedance tomography
【2h】

A combination of motion-compensated cone-beam computed tomography image reconstruction and electrical impedance tomography

机译:运动补偿锥形束计算机断层扫描图像重建和电阻抗断层扫描的组合

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Cone-beam computed tomography (CBCT) is an imaging technique used in conjunction with radiation therapy. CBCT is used to verify the position of tumours just prior to radiation treatment session. The accuracy of the radiation treatment of thoracic and upper abdominal tumours is heavily affected by respiratory movement. Blurring artefacts, due to the movement during a CBCT scanning, cause misregistration between the CBCT image and the planning image. There has been growing interest in the use of motion-compensated CBCT for correcting the breathing-induced artefacts. A wide range of iterative reconstruction methods have been developed for CBCT imaging. The direct motion compensation technique has been applied to algebraic reconstruction technique (ART), simultaneous ART (SART), ordered-subset SART (OS-SART) and conjugate gradient least squares (CGLS). In this thesis a dual modality imaging of electrical impedance tomography (EIT) and CBCT is proposed for the first time. This novel dual modality imaging uses the advantages of high temporal resolution of EIT imaging and high spatial resolution of the CBCT method. The main objective of this study is to combine CBCT with EIT imaging system for motion-compensated CBCT using experimental and computational phantoms. The EIT images were used for extracting motion for a motion-compensated CBCT imaging system. A simple motion extraction technique is used for extracting motion data from the low spatial resolution EIT images. This motion data is suitable for input into the direct motion-compensated CBCT. The performance of iterative algorithms for motion compensation was also studied. The dual modality CBCT-EIT is verified using experimental EIT system and computational CBCT phantom data.
机译:锥形束计算机断层扫描(CBCT)是一种与放射治疗结合使用的成像技术。 CBCT用于在放射治疗之前验证肿瘤的位置。胸部和上腹部肿瘤的放射治疗准确性受呼吸运动的影响很大。由于CBCT扫描过程中的移动而导致的模糊伪影会导致CBCT图像和计划图像之间的重合失调。人们对使用运动补偿CBCT来纠正呼吸引起的伪影越来越感兴趣。已经为CBCT成像开发了多种迭代重建方法。直接运动补偿技术已应用于代数重建技术(ART),同时ART(SART),有序子集SART(OS-SART)和共轭梯度最小二乘(CGLS)。本文首次提出了一种电阻抗层析成像(EIT)和CBCT的双模态成像方法。这种新颖的双模态成像利用了EIT成像的高时间分辨率和CBCT方法的高空间分辨率的优势。这项研究的主要目的是将CBCT与EIT成像系统结合起来,以使用实验和计算体模进行运动补偿的CBCT。 EIT图像用于为运动补偿的CBCT成像系统提取运动。一种简单的运动提取技术用于从低空间分辨率EIT图像中提取运动数据。该运动数据适合输入到直接运动补偿的CBCT中。还研究了运动补偿迭代算法的性能。使用实验性EIT系统和计算CBCT幻象数据验证了双模态CBCT-EIT。

著录项

  • 作者

    Pengpan Thanyawee;

  • 作者单位
  • 年度 2012
  • 总页数
  • 原文格式 PDF
  • 正文语种 English
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号