Air leakage through improperly installed recessed lighting fixtures has been identified as a common issue causing extra energy consumption of residential buildings. However, little quantitative study was found in this area. In this paper, a preliminary evaluation of the magnitude of such energy loss was conducted by numerical simulations using 3 dimensional transient computational fluid dynamics (CFD) model. A typical layout of recessed lighting fixtures was used in this case study with boundary conditions in four different seasons, which were obtained from past measured roof/attic temperature data sets. The results of the numerical simulations indicate that leakage of recessed lighting fixtures could be a very significant channel of energy loss in attic related residential buildings, especially in summer and winter time.
机译:通过不正确安装的嵌入式照明设备漏气已被认为是导致住宅建筑额外能耗的常见问题。但是,在这一领域几乎没有定量研究。在本文中,通过使用3D瞬态计算流体动力学(CFD)模型的数值模拟对这种能量损失的大小进行了初步评估。在本案例研究中,使用了嵌入式照明灯具的典型布局,并在四个不同季节中使用了边界条件,这些条件是从过去测得的屋顶/阁楼温度数据集获得的。数值模拟结果表明,嵌入式阁楼相关住宅建筑物中,嵌入式灯具的泄漏可能是非常重要的能量损失通道,尤其是在夏季和冬季。