Development and application of an ion mobility spectometer - quadrupole mass spectometer instrument

机译:离子迁移率观测仪的研制与应用 - 四极杆质谱仪

摘要

The aim of the project described in this thesis was to develop a system in house that would be capable of providing a technique to enhance the reliability of detection of threat agents such as compounds used for chemical warfare and explosives. This was to be done by using a combination of an ion mobility spectrometer (IMS) in tandem with a quadrupole mass spectrometer (QMS). When meeting these requirements, the latest electronics and software were incorporated in the instrumentation to maximise sensitivity and flexibility.udBy attaching a QMS to an IMS, an extra dimension in specificity is gained whereby a more positive identification of a compound is made based on m/z values, thereby providing further information on the ion-molecule processes taking place in the IMS. Flexibility in operation was achieved by using the graphical programming language LabVIEW for the software aspects, allowing program development and modification to be made more quickly than would be the case than if a procedural language such as C++ had been used. udA special ‘pulse to analogue’ converter developed during the project provided increased sensitivity and resolution over earlier systems in regard to obtaining selected mass mobility spectra. udProof-of-principle measurements are provided that demonstrate the capabilities of the newly developed IMS-QMS system in both positive and negative ion modes of operation, with some results obtained that are consistent with those from previous investigations. udData obtained for various chemicals not previously investigated are also provided.
机译:本文所描述的项目的目的是开发一种内部系统,该系统将能够提供一种技术,以增强检测诸如化学战和爆炸物之类的威胁剂的可靠性。这是通过结合使用离子迁移谱仪(IMS)和四极质谱仪(QMS)来完成的。当满足这些要求时,仪器中将使用最新的电子设备和软件,以最大程度地提高灵敏度和灵活性。 ud通过将IMS附加到QMS,可以获得更大的特异性,从而可以基于m进行更积极的化合物鉴定/ z值,从而提供有关IMS中发生的离子分子过程的更多信息。通过在软件方面使用图形化编程语言LabVIEW,可以实现操作的灵活性,与使用诸如C ++这样的过程语言相比,可以更快地进行程序开发和修改。 ud在该项目中开发的特殊“脉冲到模拟”转换器在获得选定的质谱迁移谱方面,比早期系统提高了灵敏度和分辨率。 ud提供了原理验证测量,这些测量证明了新开发的IMS-QMS系统在正离子和负离子操作模式下的功能,所获得的一些结果与以前的研究一致。 ud还提供了以前未研究过的各种化学药品的数据。

著录项

  • 作者

    Howse David Christopher;

  • 作者单位
  • 年度 2015
  • 总页数
  • 原文格式 PDF
  • 正文语种 English
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号