Measurement of applied force to dislodge orthodontic temporary anchorage devices

机译:测量施加力以移除正畸临时锚固装置

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Aims: To measure the force required to dislodge three different orthodontic temporary anchorage devices (TADs) from artificial test blocks and to investigate whether varying the cortical thickness of the test block will affect these forces.ududMaterials and Method: The TADs were embedded into test blocks consisting of polyurethane foam, laminated with either 2mm or 3mm short-fibre-filled epoxy sheets and a horizontal dislodging force applied, using an Instron universal testing machine. The maximum force applied before the TAD was fully dislodged was recorded. Three TADs were tested: InfinitasTM, Ancor ProTM and Ortho ImplantTM. 150 of each design were tested in the 2mm thickness test block and a further 150 of each were tested in the 3mm thickness test block.ududResults: The mean force required was 468N in the 2mm test blocks and 567N in the 3mm test blocks. No significant difference was observed between the InfinitasTM and Ancor ProTM TADs, however there was a significant difference (P>0.05) between both of these TADs and the Ortho ImplantTM. The force required in the 3mm test blocks was significantly higher than the force required in the 2mm test blocks.ududConclusion: All of the TADs were functionally acceptable, in terms of resistance to dislodgement forces. The Ortho ImplantTM required a significantly higher force to be dislodged from both the 2mm and 3mm test blocks. The thickness of the test block had a significant effect on the force required to dislodge each of the TADs.ud
机译:目的:测量从人造测试块上移出三种不同的正畸临时锚固装置(TAD)所需的力,并研究改变测试块的皮质厚度是否会影响这些力。 ud ud材料和方法:嵌入TAD使用Instron万能试验机将其倒入由聚氨酯泡沫组成的试块中,并与2mm或3mm短纤维填充的环氧片层压在一起,并施加水平位移力。记录TAD完全移出之前施加的最大力。测试了三个TAD:InfinitasTM,Ancor ProTM和Ortho ImplantTM。每个设计的150个在2mm厚度的测试块中进行测试,另外150个在3mm厚度的测试块中进行测试。 ud ud结果:在2mm的测试块中,平均力为468N,在3mm的测试块中,平均力为567N。 。在InfinitasTM和Ancor ProTM TAD之间未观察到显着差异,但是,这两个TAD与Ortho ImplantTM之间都存在显着差异(P> 0.05)。 3mm测试块所需的力显着高于2mm测试块所需的力。 ud ud结论:就抵抗脱位力而言,所有TAD在功能上都是可接受的。 Ortho ImplantTM要求从2mm和3mm试块上移出明显更大的力。测试块的厚度对移动每个TAD所需的力有很大影响。 ud

著录项

  • 作者

    Scannell John;

  • 作者单位
  • 年度 2012
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号