首页> 外文OA文献 >Light-curing units used in dentistry: factors associated with heat development – potential risk for patients
【2h】

Light-curing units used in dentistry: factors associated with heat development – potential risk for patients

机译:牙科用光固化装置:与热量发展有关的因素 - 患者的潜在风险

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objectives:To investigate how heat development in the pulp chamber and coronal surface of natural teeth with and without cusps subjected to irradiance using light-emitting diode (LED)–light-curing units (LCUs) is associated with (i) irradiance, (ii) time, (iii) distance, and (iv) radiant exposure.Materials and methods:Three different LED-LCUs were used. Their irradiance was measured with a calibrated spectrometer (BlueLight Analytics Inc., Halifax, Canada). An experimental rig was constructed to control the thermal environment of the teeth. The LED-LCU tip position was accurately controlled by a gantry system. Tooth surface temperature was measured by thermography (ThermaCAM S65 HS, FLIR Systems, Wilsonville, USA) and pulp chamber temperature with a thermocouple. LED-LCU tip distance and irradiation times tested were 0, 2, and 4 mm and 10, 20, and 30 s, respectively. Ethical permission was not required for the use of extracted teeth.Results:Maximum surface and pulp chamber temperatures were recorded in tooth without cusps (58.1 °C ± 0.9 °C and 43.1 °C ± 0.9 °C, respectively). Radiant exposure explained the largest amount of variance in temperature, being more affected by time than irradiance.Conclusions:At all combinations of variables tested, repeated measurements produced consistent results indicating the reliability of the method used. Increased exposure time seems to be the factor most likely to cause tissue damage.Clinical relevance:Risk of superficial tissue damage at irradiances >1200 mW/cm2 is evident. There is a risk of pulp damage when only thin dentin is left at higher irradiances (>1200 mW/cm2). Clinicians should be aware of LED-LCU settings and possible high temperature generated.
机译:目的:研究使用发光二极管(LED)–光固化单元(LCU)辐照的自然牙髓腔和冠状表面的热发展与(i)辐照度之间的关系,(ii时间,(iii)距离和(iv)辐射暴露。材料和方法:使用了三种不同的LED-LCU。用校准的光谱仪(加拿大哈利法克斯的BlueLight Analytics Inc.)测量其辐照度。建造了一个实验装置来控制牙齿的热环境。 LED-LCU尖端位置由龙门系统精确控制。通过热像仪(ThermaCAM S65 HS,FLIR Systems,威尔逊维尔,美国)和热电偶测量牙髓腔温度。测试的LED-LCU尖端距离和照射时间分别为0、2和4 mm,以及10、20和30 s。结果:记录没有尖头的牙齿的最高表面温度和牙髓腔温度(分别为58.1°C±0.9°C和43.1°C±0.9°C)。辐射暴露是温度变化最大的原因,受时间的影响要大于辐照度。结论:在所有测试变量的组合下,重复测量得出的结果一致,表明所用方法的可靠性。暴露时间的增加似乎是最可能导致组织损伤的因素。临床意义:辐照度> 1200 mW / cm2时表浅组织损伤的风险明显。当在较高的辐照度(> 1200 mW / cm2)下只剩下稀薄的牙本质时,存在牙髓受损的风险。临床医生应注意LED-LCU的设置以及可能产生的高温。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号