首页> 外文OA文献 >Comparison between refractometer and retinoscopy in determining refractive errors in children--false doubt.
【2h】

Comparison between refractometer and retinoscopy in determining refractive errors in children--false doubt.

机译:折射计与检影法在确定儿童屈光不正中的比较 - 虚假怀疑。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Early detection of a refractive error and its correction are extremely important for the prevention of amblyopia (poor vision). The golden standard in the detection of refractive errors is retinoscopy--a method where the pupils are dilated in order to exclude accomodation. This results in a more accurate measurement of a refractive error. Automatic computer refractometer is also in use. The study included 30 patients, 15 boys, 15 girls aged 4-16. The first examination was conducted with refractometer on narrow pupils. Retinoscopy, followed by another examination with refractometer was performed on pupils dilated with mydriatic drops administered 3 times. The results obtained with three methods were compared. They indicate that in narrow pupils the autorefractometer revealed an increased diopter value in nearsightedness (myopia), the minus overcorrection, whereas findings obtained with retinoscopy and autorefractometer in mydriasis cycloplegia, were much more accurate. The results were statistically processed, which confirmed the differences between obtained measurements. These findings are consistent with the results of studies conducted by other authors. Automatic refractometry on narrow pupils has proven to be a method for detection of refractive errors in children. However, the exact value of the refractive error is obtained only in mydriasis--with retinoscopy or an automatic refractometer on dilated pupils.
机译:早期发现屈光不正及其矫正对于预防弱视(视力低下)极为重要。检影屈光不正的黄金标准是检影法-这种方法是将瞳孔扩大以排除调节。这样可以更精确地测量屈光不正。自动计算机折射仪也正在使用中。该研究包括30位患者,15位男孩,15位4-16岁的女孩。第一次检查是使用折射仪对狭窄的瞳孔进行的。检影,然后用屈光计进行另一次检查,对散瞳散瞳3次的散瞳瞳孔进行3次检查。比较了用三种方法获得的结果。他们表明,在狭窄的瞳孔中,自动验光仪显示近视(近视)的屈光度值增加,减去过度矫正,而通过检影镜和自动验光仪在散瞳睫状肌麻痹中获得的结果更为准确。对结果进行统计处理,这证实了获得的测量之间的差异。这些发现与其他作者的研究结果一致。事实证明,对狭窄瞳孔进行自动验光是检测儿童屈光不正的一种方法。但是,屈光不正的确切值仅在散瞳中获得-使用检影镜或自动验光仪在散瞳上进行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号