首页> 外文OA文献 >Calibration of an interferometric surface measurement system on an ultra-precision turning lathe
【2h】

Calibration of an interferometric surface measurement system on an ultra-precision turning lathe

机译:在超精密车床上校准干涉表面测量系统

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

On-machine measurement avoids the time-consuming transposition operations between the measurement and machine coordinates. The present work integrates an interferometric probing system on an ultra-precision turning machine. Due to the relatively harsh environment in the machine tools, metrological characteristics of the surface measurement instrument would deviate from those tested under standard laboratory conditions. In order to improve the performance of on-machine measurement systems, it is necessary to calibrate the on-machine measurement (OMM) system and compensate for any systematic errors. Three key issues, including on-machine vibration, machine tool kinematics error, and linearity error are discussed in this study. Experimental investigation is conducted to prove the validity of proposed calibration methodology and the effectiveness of on-machine measurement.
机译:机器上的测量避免了在测量和机器坐标之间进行费时的换位操作。目前的工作在超精密车床上集成了干涉探测系统。由于机床环境相对恶劣,表面测量仪器的计量特性将与在标准实验室条件下测试的那些特性有所不同。为了提高机上测量系统的性能,有必要校准机上测量(OMM)系统并补偿任何系统误差。本研究讨论了三个关键问题,包括机床振动,机床运动学误差和线性误差。进行实验研究以证明所提出的校准方法的有效性以及在机测量的有效性。