From 1987 through 1992 the Las Vegas Flamingo Hilton instituted resource efficiency improvements in electrical, natural gas, water and materials consumption. In 1992, the Flamingo Hilton commissioned the University of Nevada Las Vegas Environmental Studies Department to analyze and quantify the improvements made by The Flamingo Hilton and investigate the potential for further improvements.Historical billing data from the periods 1987 - 1992 were used to analyze past and present (1992) electric, natural gas and water consumption. Materials disposal data was only available for a ten month period in 1992. Pollutant emissions data were supplied by Nevada Power Company.The efficiency improvements resulted in an annual cost savings of $412,344 and reduction in annual emissions of CO2 by 5245 tons, SO2 by 1.4 tons and NOX by 14 tons.A second objective of this project was to examine current resource consumption and identify areas where additional improvements could be realized. It was determined that the analysis would be concentrated on the hotelu27s lighting system because of the large potential for savings that remained in this area. The EROAP project team formulated a resource efficiency optimization plan for the facilityu27s lighting systems which will provide an additional annual cost savings $280,498 and annual emissions reductions of CO2 by 4,548 tons, SO2 by 1.4 tons and NOX by 12.4 tons.
机译:从1987年到1992年,拉斯维加斯火烈鸟希尔顿酒店在电,天然气,水和材料的消耗方面提高了资源效率。 1992年,弗拉明戈·希尔顿(Flamingo Hilton)委托内华达大学拉斯维加斯环境研究系对弗拉明戈·希尔顿(Flamingo Hilton)所做的改进进行分析和量化,并研究进一步改进的潜力。1987年至1992年的历史计费数据用于分析过去和过去目前(1992年)的电力,天然气和水消耗量。仅提供1992年10个月的材料处理数据。内华达州电力公司提供了污染物排放数据。效率的提高导致每年节省了412,344美元的成本,并且每年减少了CO2排放量5245吨,SO2排放量1.4吨NOX排放量为14吨。该项目的第二个目标是检查当前的资源消耗并确定可以实现进一步改进的领域。已确定分析将集中在酒店的照明系统上,因为该地区仍具有巨大的节省潜力。 EROAP项目团队为该设施的照明系统制定了资源效率优化计划,该计划将额外节省280,498美元的年度成本,并每年减少CO2排放量4,548吨,SO2排放量1.4吨和NOX排放量12.4吨。

著录项

  • 作者

    Nowlin Dennis;

  • 作者单位
  • 年度 1996
  • 总页数
  • 原文格式 PDF
  • 正文语种 English
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号