This contribution investigates the effect of changed network topologies within HV systems on component level EMC tests. Therefore the recent state of art in component level testing is presented and the differences of LV and HV network topologies are discussed. An adaption of the component level test setup for HV components is introduced and a minimized HV system investigated. Results of a case study on an inverter for a hybrid car are presented and the impact of the measurements in the design of HV systems will be discussed.