首页> 外文OA文献 >TEST METHOD VERIFICATION OF Fe AND SiO2 IN INDUSTRIAL WATERudBY UV-VIS SPECTROPHOTOMETRY AT PT KRAKATAU STEEL
【2h】

TEST METHOD VERIFICATION OF Fe AND SiO2 IN INDUSTRIAL WATERudBY UV-VIS SPECTROPHOTOMETRY AT PT KRAKATAU STEEL

机译:工业用水中Fe和siO2的测试方法验证通过pT KRaKaTaU钢的UV-VIs分光光度法测定

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

It has been conducted the test methods verification of Fe and SiO2 in industrial waterudusing UV-Vis spectrophotometer at PT Krakatau Steel. Verification parameters testedudwere linearity, precision, accuracy, and detection limit. The results show the value ofudlinearity, precision, accuracy and detection limits for testing Fe are respectively 0.996;ud3.803%; 87.94% and 0.048 mg/L while for SiO2 consecutive tests was 0.998; 2.014%;ud100.755% and 0.010 mg/L. The results of test methods verification of Fe and SiO2 meetudthe requirements and can be accepted as a method for routine testing in the chemicaludlaboratory of PT Krakatau Steel.
机译:PT Krakatau钢铁公司已经使用紫外可见分光光度计对工业用水中的Fe和SiO2进行了测试方法验证。测试的验证参数为线性,精度,准确性和检测极限。结果表明:Fe的线性,精密度,准确度和检出限分别为0.996; ud3.803%;分别为87.94%和0.048 mg / L,而SiO2连续测试为0.998; 2.014%; ud100.755%和0.010 mg / L。 Fe和SiO2的测试方法验证的结果符合要求,可以作为PT Krakatau钢的化学/实验室的常规测试方法。