首页> 外文OA文献 >An experimental study of air flow and temperature distribution in a room with displacement ventilation and a chilled ceiling
【2h】

An experimental study of air flow and temperature distribution in a room with displacement ventilation and a chilled ceiling

机译:置换通风和冷藏天花板房间气流和温度分布的实验研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Displacement ventilation and chilled ceiling panel systems are potentially more energy efficient than conventional air conditioning systems and are characterized by the presence of vertical temperature gradients and significant radiant asymmetry. The characteristics of this type of system have been studied by making temperature and air flow measurements in a test chamber over a range of operating parameters typical of office applications. Results from the displacement ventilation study are consistent with other studies and show that normalized temperature profiles are independent of internal heat gain. Linear temperature gradients in the lower part of the room were found, in all cases, to be driven by convection from the adjacent walls. Significant mixing, indicated by reduced temperature gradients, was evident in the upper part of the room in the chilled ceiling results at higher levels of heat gain. Visualization experiments, velocity measurements and related numerical studies indicated that with greater heat gains the plumes have sufficient momentum to drive flow across the ceiling surface and down the walls. The significance of forced, as opposed to natural convection, is also suggested by relatively low Richardson Number (Ri) values found near the ceiling. Furthermore, in cases with moderately high internal gains, comparison of the temperature gradients indicated that the effect of ceiling surface temperature on the degree of mixing and the magnitude of the temperature gradient were of secondary importance. These findings are in contrast to the view that it is natural convection at the ceiling that causes enhanced mixing.
机译:置换通风和冷藏天花板系统可能比常规空调系统更节能,并且其特征在于存在垂直温度梯度和明显的辐射不对称性。已经通过在办公室应用中典型的一系列操作参数范围内在测试室内进行温度和空气流量测量来研究此类系统的特性。置换通风研究的结果与其他研究一致,表明归一化温度曲线与内部热量获取无关。在所有情况下,都发现房间下部的线性温度梯度是由相邻墙的对流驱动的。在较高的热量获取水平下,在冷藏天花板的房间上部,明显的混合(由降低的温度梯度表示)。可视化实验,速度测量和相关的数值研究表明,随着热量的增加,羽流具有足够的动量来驱动流过天花板表面并向下流动到墙壁。与自然对流相反,在天花板附近发现相对较低的理查森数(Ri)值也表明了强迫的重要性。此外,在内部增益适度较高的情况下,温度梯度的比较表明,顶面温度对混合度和温度梯度大小的影响是次要的。这些发现与在天花板上自然对流导致增强混合的观点相反。

著录项

  • 作者

    Rees SJ; Haves P;

  • 作者单位
  • 年度 2013
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号