Experimental Investigation of Heat Removal Factor in Solar Flat Plate Collector for Various Flow Configurations

机译:不同流动形式的太阳能平板集热器散热系数的实验研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This paper reports the performance of a solar flat plate collector for various flow configurations and presents a comparative evaluation. Three cases have been discussed: (i) serpentine flow, (ii) parallel-wall-to-wall flow, and (iii) spiral flow. The heat removal factor (FR) is the ratio of the actual heat transfer to the maximum possible heat transfer through the collector plate. A special case showing the effect of phase change material (PCM) on FR in the case of serpentine is discussed. A sheet-and-tube type collector where the tubes are bonded to the absorber plate by a suitable adhesive is considered. Equations showing the dependence of FR on the fin factor were studied and indoor experiments were conducted to determine the value of FR. Finally, a numerical investigation was done and comparisons were evaluated. Results indicate that when the mass flow rate (⋅m) of water is 1, the value of FR for serpentine and parallel wall-to-wall flow is 0.44 and 0.88, respectively. It was also observed that for the case of PCM, FR is a variable quantity and its value ranges from 0 to 0.28. In this case, FR is a function of the PCM melting and solidifying phases rather than mass flow and is proportional to the melting temperature of the PCM. Also, it is observed that in a conventional water heater with serpentine flow or parallel wall-to-wall flow, the value of FR does not increase significantly beyond a mass flow rate (⋅m) of 4 kg/hr.
机译:本文报告了太阳能平板集热器在各种流动配置下的性能,并提出了比较评估。讨论了三种情况:(i)蛇形流,(ii)平行壁到壁流和(iii)螺旋流。排热系数(FR)是实际热传递与通过集热板的最大可能热传递之比。讨论了显示蛇纹石情况下相变材料(PCM)对FR的影响的特殊情况。考虑一种板管式集热器,其中管通过合适的粘合剂粘结到吸收板上。研究了表明FR对鳍因子的依赖性的方程,并进行室内实验以确定FR的值。最后,进行了数值研究并评估了比较结果。结果表明,当水的质量流率(⋅m)为1时,蛇形流和平行壁对壁流的FR值分别为0.44和0.88。还观察到,对于PCM,FR是一个可变量,其值的范围是0到0.28。在这种情况下,FR是PCM熔化和固化阶段的函数,而不是质量流量的函数,并且与PCM的熔化温度成正比。此外,可以观察到,在具有蛇形流动或平行的壁对壁流动的常规热水器中,FR的值不会明显超过4 kg / hr的质量流率(m)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号