首页> 外文OA文献 >CFD modelling of transient pathogen release in indoor environments due to human activity
【2h】

CFD modelling of transient pathogen release in indoor environments due to human activity

机译:由人类活动引起的室内环境中瞬态病原体释放的CFD模拟

摘要

Certain routine hospital activities have been identified as a potential source for the airborne dispersal of micro-organisms. With increasing use of CFD to model hospital situations a method of modelling this type of spread within a simple steady state model is required. Since this type of dispersal will vary with space and time a single point source would not provide adequate information to represent these sources. Instead a zonal bioaerosol source isudintroduced to represent the time average of the varying release from the activity. In this paper, data from experiments conducted in a bioaerosol test chamber are compared to CFD results.udNumerical validation is also carried out comparing the zonal source to an equivalent transient source. The results indicate that the zonal source provides excellent comparison to the time averaged behaviour of a moving source, but greatly underestimates the maximum value at anyudone location.
机译:某些常规的医院活动已被确定为微生物通过空气传播的潜在来源。随着越来越多地使用CFD对医院情况进行建模,需要一种在简单的稳态模型中对这种类型的传播进行建模的方法。由于这种类型的分散会随空间和时间而变化,因此单点源将无法提供足够的信息来表示这些源。相反,引入了带状生物气溶胶源来代表从活动中释放的时间平均值。在本文中,将在生物气溶胶测试室中进行的实验数据与CFD结果进行了比较。 ud还对区域源与等效瞬态源进行了数值验证。结果表明,纬向源与移动源的时间平均行为提供了出色的比较,但大大低估了任何 udone位置的最大值。

著录项