首页> 外文OA文献 >Clinical applications of intra-cardiac four-dimensional flow cardiovascular magnetic resonance: A systematic review
【2h】

Clinical applications of intra-cardiac four-dimensional flow cardiovascular magnetic resonance: A systematic review

机译:心内四维血流心血管磁共振的临床应用:系统综述

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

BACKGROUND: Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is an emerging non-invasive imaging technology used to visualise and quantify intra-cardiac blood flow. The aim of this systematic review is to assess the literature on the current clinical applications of intra-cardiac 4D flow CMR. METHODS: A systematic review was conducted to evaluate the literature on the intra-cardiac clinical applications of 4D flow CMR. Structured searches were carried out on Medline, EMBASE and the Cochrane Library in October 2016. A modified Critical Skills Appraisal Programme (CASP) tool was used to objectively assess and score the included studies. Studies were categorised as 'highly clinically applicable' for scores of 67-100%, 'potentially clinically applicable' for 34-66% and 'less clinically applicable' for 0-33%. RESULTS: Of the 1608 articles screened, 44 studies met eligibility for systematic review. The included literature consisted of 22 (50%) mechanistic studies, 18 (40.9%) pilot studies and 4 (9.1%) diagnostic studies. Based on the modified CASP tool, 27 (62%) studies were 'highly clinically applicable', 9 (20%) were 'potentially clinically applicable' and 8 (18%) were 'less clinically applicable'. CONCLUSIONS: There are many proposed methods for using 4D flow CMR to quantify intra-cardiac flow. The evidence base is mainly mechanistic, featuring single-centred designs. Larger, multi-centre studies are required to validate the proposed techniques and investigate the clinical advantages that 4D flow CMR offers over standard practices. PROSPERO=CRD42016051438.
机译:背景:二维流心血管磁共振(4D流CMR)是一种新兴的非侵入性成像技术,用于可视化和量化心脏内的血流。本系统综述的目的是评估有关心脏内4D流CMR当前临床应用的文献。方法:进行了系统评价,以评估有关4D流式CMR在心脏内临床应用的文献。于2016年10月在Medline,EMBASE和Cochrane图书馆进行了结构化搜索。使用改良的关键技能评估程序(CASP)工具客观评估和评分纳入研究。研究分为67-100%的“高度临床适用”,34-66%的“潜在临床适用”和0-33%的“临床较少”。结果:在筛选的1608篇文章中,有44项研究符合资格进行系统评价。纳入的文献包括22项(50%)机理研究,18项(40.9%)初步研究和4项(9.1%)诊断研究。基于改进的CASP工具,有27个(62%)研究“具有较高的临床适用性”,9个(20%)具有“潜在的临床适用性”和8个(18%)具有“较低的临床适用性”。结论:有许多提议的使用4D流量CMR量化心脏内流量的方法。证据基础主要是机械的,具有单中心设计。需要更大的,多中心的研究来验证所提出的技术并调查4D流CMR提供的优于标准实践的临床优势。 PROSPERO = CRD42016051438。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号