Auto-refrigerating cascade (ARC) systems possess many advantages comparing with traditional cascade refrigeration systems. This work proposed a novel ternary mixture, R600a/R23/R14, for ARC systems for 190 K applications. The performance of the ternary mixture and the influences of compositional ratio and bypass scheme were assessed in a modified domestic cooler. The results demonstrated the feasibility of the proposed R600a/R23/ R14 ternary mixture as an environmental benign alternative for ARC systems. The performance varied little within a certain composition range and a mass ratio of 35/30/35 for R600a/R23/R14 mixture was recommended. It also showed that the two bypass schemes, which can regulate more effectively the refrigerant compositions, were better than the conventional hot-gas bypass approach. The variation of the evaporator temperature suggested the presence of local dryout at high heat loads (i.e., larger than the design value), which should be carefully prevented.
展开▼