Optimization of capactive microphone and pressure sensor performance by capacitor-electrode shaping

机译:通过电容器 - 电极成形优化电容式麦克风和压力传感器的性能

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In many designs of capacitive microphones or pressure sensors the electrode size is chosen to be equal to the diaphragm size. In this paper it will be discussed whether an electrode size or shape that differs from that of the diaphragm is attractive for obtaining a maximum value for the sensor sensitivity and the signal-to-noise ratio. A theoretical analysis will be given for circular diaphragms and electrodes, from which it can be shown that for maximum sensitivity the electrode should be located at the centre of the diaphragm, with a radius depending on the value of the amplifier input capacitance.
机译:在电容式麦克风或压力传感器的许多设计中,电极尺寸选择为等于膜片尺寸。在本文中,将讨论与隔膜不同的电极尺寸或形状是否对获得传感器灵敏度和信噪比的最大值具有吸引力。将对圆形膜片和电极进行理论分析,从中可以看出,为了获得最大灵敏度,电极应位于膜片的中心,其半径取决于放大器输入电容的值。