摘要

Liquid phase mass transfer rates kLS for the absorption of oxygen in tap water and in aqueous ionic solutions have been determined in two closed stirred tank contactors for a power input between 3 and 70 W/kg and (impeller diameter)f(tank diameter) ratios DifT of 0.3, 0.35 and 0.4. The contactors had diametersudof 0. I9 and 0.6 m. The dispersed phase fraction was 1% by volume in all experiments. The values of kLS were determined using two different techniques:ud(1) a transient physical absorption method; and (2) the sulphite method.
机译:已经在两个密闭的搅拌釜接触器中确定了在3至70 W / kg的功率输入和(叶轮直径)f(罐直径)之比的功率输入下,在自来水和离子水溶液中吸收氧气的液相传质速率kLS DifT为0.3、0.35和0.4。接触器的直径为 udof0。I9为0.6 m。在所有实验中,分散相的分数为1体积%。 kLS的值使用两种不同的技术确定: ud(1)瞬态物理吸收法; (2)亚硫酸盐法。