首页> 外文OA文献 >Analysis of phenols by high-performance liquid chromatography with pre-column derivatization by 2-(9-carbazole)-ethyl-chloroformate
【2h】

Analysis of phenols by high-performance liquid chromatography with pre-column derivatization by 2-(9-carbazole)-ethyl-chloroformate

机译:2-(9-咔唑) - 乙基氯甲酸酯柱前衍生高效液相色谱法分析苯酚

摘要

2-(9-Carbazole)-ethyl-chloroformate (CEOC), a novel pre-column fluorescence labeling reagent, has been synthesized and applied for the derivatization of phenols. Taken phenol, p-chlorophenol, 2,5-dimethylphenol, 2,4-dichlorophenol and 1,4-dihydroxybenzene as testing standards, the effects of derivatization conditions, such as pH of borate buffer, reaction time and fluorescent tagging reagent concentration, have been systematically studied. Under the optimized conditions, CEOC reacts readily with the phenols to form stable derivatives with excitation and emission wavelengths, respectively, at 293 and 360 nm. The single step derivatization reaction could be finished within 20 min even at room temperature. Such a method has been successfully applied to the analysis of phenols in printing ink by high-performance liquid chromatography. (c) 2005 Elsevier B.V. All rights reserved.
机译:合成了一种新型的柱前荧光标记试剂2-(9-咔唑)-氯甲酸乙酯(CEOC),并将其用于苯酚的衍生化。以苯酚,对氯苯酚,2,5-二甲基苯酚,2,4-二氯苯酚和1,4-二羟基苯为检测标准,对衍生条件的影响,如硼酸盐缓冲液的pH值,反应时间和荧光标记试剂的浓度被系统地研究了。在最佳条件下,CEOC容易与酚反应,形成稳定的衍生物,其激发和发射波长分别在293和360 nm。即使在室温下,一步衍生化反应也可以在20分钟内完成。该方法已成功应用于高效液相色谱法分析印刷油墨中的酚。 (c)2005 Elsevier B.V.保留所有权利。