BACKGROUND: Resonance frequency (RF) analysis is frequently used to monitor implant stability in patients. The influence of transducer orientation on RF of implants placed in jawbone has not been evaluated.\udPURPOSE: The aim of this study was to evaluate to what extent transducer orientation influences RF. The second aim was to evaluate if measurements taken with any particular orientation would best relate to marginal bone levels.\udMATERIALS AND METHODS: Nine patients edentulous in the upper jaw received 55 implants 3 years before this study. They underwent clinical and radiographic evaluation. Using Osstell (Integration Diagnostics AB, Göteborg, Sweden), four RF measurements were made for each implant. Measurements were obtained with the transducer cantilever placed buccally (B), distally (D), palatally (P), and mesially (M).\udRESULTS: All implants were clinically stable. Significant differences resulted between the measurements perpendicular to the bony crest (B, P) and the parallel ones (M, D). A tendency of negative correlation was found between marginal bone levels and implant stability quotient (ISQ) measurements; however, this correlation was not statistically significant.\udCONCLUSIONS: In conclusion, when measuring the RF of dental implants using the Osstell, it has to be taken into account that the transducer orientation influences the measurement. It seems therefore advisable to standardize the orientation. Moreover, although there was a tendency, any statistical significant correlation between ISQ values and marginal bone levels could not be established.
机译:背景:共振频率(RF)分析通常用于监测患者的植入物稳定性。尚未评估换能器方向对放置在颌骨中植入物RF的影响。\目的:本研究的目的是评估换能器方向在多大程度上影响RF。第二个目的是评估以任何特定方向进行的测量是否最能与边缘骨水平相关。\材料与方法:9名上颌无牙的患者在这项研究之前3年接受了55颗种植体。他们进行了临床和放射学评估。使用Osstell(瑞典哥德堡集成诊断公司,Integration Diagnostics AB),对每个植入物进行了四个RF测量。探头悬臂放置在颊侧(B),远侧(D),me骨(P)和近中(M)的位置获得了测量结果。\结果:所有植入物在临床上均稳定。垂直于骨峰的测量值(B,P)与平行峰的测量值(M,D)之间存在显着差异。发现边缘骨水平与植入物稳定性商(ISQ)测量值之间呈负相关趋势。结论:总之,当使用Osstell测量牙科植入物的RF时,必须考虑换能器的方向会影响测量。因此,建议将方向标准化。而且,尽管存在这种趋势,但ISQ值与边缘骨水平之间没有任何统计上的显着相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号