首页> 外文OA文献 >2-D Heat Transfer Model of A Horizontal U-Tube
【2h】

2-D Heat Transfer Model of A Horizontal U-Tube

机译:水平U形管的二维传热模型

摘要

Paying attention to the shallow ground heat inside a tunnel, a Horizontal U-Tube (HUT) road heating system was introduced for the first time in Japan in order to prevent winter traffic accidents associated with road freezing at the west side mouth of Nanaori-Toge tunnel, Aizu-bange, Fukushima Prefecture. Horizontal U-tubes were buried at a depth of 1.2 m in the ground of the central part of the tunnel. The ground heat extracted by the HUT is injected into the anti-freezing pavement at the tunnel mouth. In this study, attempts were made to propose a simplified heat transfer model of HUT system. The proposed model consists of the energy balance equations of the fluid circulating in the HUT and the surrounding ground. Solving these two equations simultaneously, the extracted ground heat could be calculated as well as the fluid and ground temperatures. The model could also lead the overall heat transfer coefficient between the fluid and the surrounding ground. The validity of the model was accepted from the comparison with indoor experimental results using a miniature HUT.
机译:为了防止隧道内的地热较浅,日本首次引入了水平U型管(HUT)道路供暖系统,以防止与Nanaori-Toge西侧道路冻结相关的冬季交通事故福岛县会津邦古隧道。水平U型管埋在隧道中央部分地面1.2 m处。 HUT提取的地热被注入隧道口处的防冻路面。在这项研究中,尝试提出一种简化的HUT系统传热模型。所提出的模型由HUT和周围地面中循环的流体的能量平衡方程组成。同时求解这两个方程,可以计算提取的地热以及流体和地面的温度。该模型还可以引导流体与周围地面之间的总传热系数。通过使用微型HUT与室内实验结果进行比较,可以接受模型的有效性。