As an alternative to conventional dynamic pile installation methods, pile jacking is an environmentally friendly technique that could become more widely accepted. Great concern has arisen over the performance of jacked piles as compared with that of driven piles. This paper describes a comprehensive field study that was aimed at investigating the differences and similarities between the behaviour of jacked H-piles and that of driven H-piles. The instrumented piles, varying in length from 32 to 55 m and having a design capacity of up to 3540 kN, were installed in residual soils whose properties are close to silty sands. The load test results indicate that the shaft resistance of jacked piles is generally suffer and stronger than that of driven piles, but the base resistance of jacked piles is weaker than that of driven piles. At a load level of twice the design capacity, the percentage of pile head load carried by base varies from 2% to 10% for jacked piles, with a mean value of 6%; for driven piles the percentage varies from 6% to 61% with a mean value of 38%. The back-calculated values of the shaft friction coefficient, β, were found to be in a range of 0.25-0.6 for both jacked and driven piles. A correlation was also observed between the ultimate shaft friction and the mean standard penetration test N value (N̄), which suggests that the shaft friction can be taken as 1.5N̄ to 2N̄ (kPa) for both jacked and driven H-piles.
机译:作为传统动态桩安装方法的替代方法,顶桩是一种环保技术,可能会被越来越广泛地接受。与压入桩相比,压入桩的性能引起了人们的极大关注。本文介绍了一项全面的现场研究,旨在研究顶升H桩和从动H桩的行为之间的异同。桩长从32到55 m不等,设计能力高达3540 kN,被安装在性质接近粉砂的残余土壤中。载荷试验结果表明,顶进桩的竖向阻力通常比打入桩承受且强,而顶进桩的基础阻力却比打入桩的弱。在两倍于设计承载力的荷载水平下,千斤顶桩基所承受的桩头荷载百分比从2%到10%不等,平均值为6%。对于打桩,百分比从6%到61%不等,平均值为38%。对于千斤顶和打入桩,竖向摩擦系数β的反算值都在0.25-0.6的范围内。在最终的轴摩擦力与平均标准渗透试验N值(N̄)之间也发现了一种相关性,这表明对于顶升和从动H型桩,轴摩擦力可以取为1.5N̄至2N̄(kPa)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号