首页> 外文OA文献 >The impact of uncertainties associated with MammoSite brachytherapy on the dose distribution in the breast
【2h】

The impact of uncertainties associated with MammoSite brachytherapy on the dose distribution in the breast

机译:与mammosite近距离放射治疗相关的不确定性对乳房剂量分布的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The MammoSite radiation therapy system is a novel technique for treatment of patients with early-stage breast cancer. It was developed to overcome the longer schedules associated with external-beam radiation therapy. It consists of a small balloon (4 cm in diameter) connected to an inflation channel and a catheter for the passage of a high dose rate 192Ir brachytherapy source. The device is placed into the tumor resection cavity and inflated with a mixture of saline and radiographic contrast agent to a size that fills the cavity. A high dose rate 192Ir source is driven into the balloon center using a remote afterloader to deliver the prescribed dose at a point 1 cm away from the balloon surface. There are several uncertainties that affect the dose distribution in the MammoSite brachytherapy. They include source position deviation, balloon deformation, and the concentration of the contrast medium inside the balloon. The purpose of this study is to investigate the extent of the dose perturbation for various concentrations of the contrast medium in a MammoSite balloon using Monte Carlo simulations and thermoluminescent dosimetry. This study also combines the impact of these uncertainties on the MammoSite treatment efficacy. The current study demonstrates that the combined uncertainties associated with the MammoSite brachytherapy technique--up to the value of 2 mm balloon deformation, 1 mm source deviation, and 15% contrast concentration--have no impact on the tumor control probability.
机译:MammoSite放射治疗系统是一种用于治疗早期乳腺癌患者的新技术。它的开发是为了克服与外部束放射疗法相关的更长的时间表。它由一个与充气通道相连的小气球(直径4厘米)和一个用于使高剂量率192Ir近距离放射治疗源通过的导管组成。将该装置放入肿瘤切除腔中,并用盐水和X射线造影剂的混合物充气至充满腔的大小。使用远程后装载器将高剂量率192Ir源驱动到球囊中心,以在距球囊表面1 cm的位置输送指定剂量。在MammoSite近距离放射治疗中,存在一些不确定因素会影响剂量分布。它们包括源位置偏差,球囊变形以及球囊内造影剂的浓度。这项研究的目的是使用蒙特卡洛模拟和热发光剂量法研究MammoSite气球中各种浓度的造影剂的剂量扰动程度。这项研究还结合了这些不确定性对MammoSite治疗功效的影响。当前的研究表明,与MammoSite近距离放射治疗技术相关的综合不确定性-高达2 mm的球囊变形,1 mm的放射源偏差和15%的造影剂浓度-对肿瘤的控制概率没有影响。

著录项

  • 作者

    Bensaleh, S.; Bezak, E.;

  • 作者单位
  • 年度 2011
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号