首页> 外文OA文献 >Analytical thermal rating method for cables installed in J-tubes
【2h】

Analytical thermal rating method for cables installed in J-tubes

机译:安装在J形管中的电缆的分析热额定值法

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

One possible thermal pinch point along the route of a wind farm export circuit is a J tube, commonly used to provide mechanical protection to cable sections between the sea floor and the offshore platform. Current ratings for such cable sections are not covered by the scope of IEC 60287, while the existing publications covering such systems have limitations. This paper presents an updated 2D analytical method and a 3D extension for the rating of J tubes with short air section lengths. Continuous rating comparisons have been made against a 3D finite element model which shows a 4.5% variation in rating from the 2D analytical model for air section lengths greater than 10 m, rising to 13% for short air section lengths. With the addition of longitudinal heat transfer within the new 3D analytical approach this variation decreases by 2.5%. Both methods proposed can be solved readily using conventional spreadsheet tools and are broadly compliant with the IEC 60287 methodology.
机译:沿着风电场出口回路的路线的一个可能的热收缩点是J型管,通常用于为海底和海上平台之间的电缆部分提供机械保护。 IEC 60287的范围不包括此类电缆的额定电流,而有关此类系统的现有出版物存在局限性。本文提出了一种更新的2D分析方法和3D扩展,用于短空气段长度的J管的额定值。已对3D有限元模型进行了连续的额定值比较,该模型显示了2D分析模型中大于10 m的空气段长度的额定值变化了4.5%,对于较短的空气段长度则上升到13%。在新的3D分析方法中增加了纵向传热,这种变化减少了2.5%。所提出的两种方法都可以使用常规的电子表格工具轻松解决,并且广泛符合IEC 60287方法。