首页> 外文OA文献 >Relation between vibrotactile perception thresholds and reductions in finger blood flow induced by vibration of the hand at frequencies in the range 8–250 Hz
【2h】

Relation between vibrotactile perception thresholds and reductions in finger blood flow induced by vibration of the hand at frequencies in the range 8–250 Hz

机译:振动触觉感知阈值与手振动引起的手指血流减少之间的关系,频率范围为8-250 Hz

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose: this study investigated how the vasoconstriction induced by vibration depends on the frequency of vibration when the vibration magnitude is defined by individual thresholds for perceiving vibration [i.e. sensation levels (SL)].Methods: fourteen healthy subjects attended the laboratory on seven occasions: for six vibration frequencies (8, 16, 31.5, 63, 125, or 250 Hz) and a static control condition. Finger blood flow (FBF) was measured in the middle fingers of both hands at 30-second intervals during five successive periods: (i) no force or vibration, (ii) 2-N force, no vibration, (iii) 2-N force, vibration, (iv) 2-N force, no vibration, (v) no force or vibration. During period (iii), vibration was applied to the right thenar eminence via a 6-mm diameter probe during ten successive 3-min periods as the vibration magnitude increased in ten steps (?10 to +40 dB SL).Results: with vibration at 63, 125, and 250 Hz, there was vasoconstriction on both hands when the vibration magnitude reached 10 dB SL. With vibration at 8, 16, and 31.5 Hz, there was no significant vasoconstriction until the vibration reached 25 dB SL. At all frequencies, there was greater vasoconstriction with greater magnitudes of vibration.Conclusions: it is concluded that at the higher frequencies (63, 125, and 250 Hz), the Pacinian channel mediates vibrotactile sensations near threshold and vasoconstriction occurs when vibration is perceptible. At lower frequencies (8, 16, and 31.5 Hz), the Pacinian channel does not mediate sensations near threshold and vasoconstriction commences at greater magnitudes when the Pacinian channel is activated
机译:目的:这项研究调查了当由各个感知振动的阈值确定振动幅度时,由振动引起的血管收缩如何取决于振动频率。方法:十四名健康受试者在七个场合参加了实验室:六个振动频率(8、16、31.5、63、125或250 Hz)和静态控制条件。在连续五个周期中,以30秒的间隔在两只手的中指中测量手指血流量(FBF):( i)无力或无振动;(ii)2-N力,无振动;(iii)2-N力,振动,(iv)2-N力,无振动,(v)没有力或振动。在第(iii)阶段中,随着振动幅度以10步(?10至+40 dB SL)的幅度增加,在连续10分钟的3分钟内通过6毫米直径的探头将振动施加到右下角隆起。在63、125和250 Hz时,当振动幅度达到10 dB SL时,两只手都有血管收缩。在8、16和31.5 Hz的振动下,直到振动达到25 dB SL之前,才没有明显的血管收缩。结论:结论:在较高的频率(63、125和250 Hz)下,Pacinian通道在阈值附近介导了触觉振动,并且在可察觉振动时发生了血管收缩。在较低的频率(8、16和31.5 Hz)下,Pacinian通道在激活Pacinian通道时不会调解阈值附近的感觉,并且血管收缩开始时幅度更大

著录项

  • 作者

    Ye, Ying; Griffin, Michael J.;

  • 作者单位
  • 年度 2014
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号