Reliability Case Notes No. 4: Autosub6000 and Autosub3 actuator potentiometer failure analysis and testing report

机译:可靠性案例说明第4号:autosub6000和autosub3执行器电位器故障分析和测试报告

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

During the James Cook Cruise 27 Autosub6000 aborted mission 12 due to a failure in the position feedback potentiometer of the stern plane actuator. The same actuator is used on Autosub3 which is heading to the Pine Island glacier in Antarctica in January 2009. A similar failure of the Autosub3 actuator while under the ice would result in the loss of the AUV.This report initially describes the investigation into the failure of the feedback potentiometer and shows that the potentiometer’s conductive plastic track became detached from its ceramic substrate and broke up. The report then describes the testing performed to evaluate the reliability of the potentiometer. This involved an accelerated aging test to simulate the worst case conditions seen by the potentiometer in the actuator. This was achieved by oscillating the potentiometer at 4Hz to simulate the actuator movements whilst cycling the pressure of the Morlina 10 oil surrounding the potentiometers.During the testing the 10k? potentiometers used in the actuator were not available, and so 5k? potentiometers from the same range were tested as a substitute. It was assumed that these 5k? potentiometers would produce similar results, however it was found during the testing that the formulation of the 5k? potentiometer track was different from the 10k?; whether this affects the reliability is not known.Due to the large amount of time required to perform each test only 16 5k? potentiometers were tested. Although no failures occurred, the sample was too small to give a high statistical confidence that the potentiometers would survive the cruise. To further reduce the risk four 5k? potentiometers that were to be used on Autosub3 were tested for approximately 72 hours in a ‘burnt in’ process. As an early failure similar to that of Autosub6000 potentiometer would have been detected during this process, the chance of the potentiometers failing was significantly reduced. Thus the burnt in potentiometers were considered acceptable for use on Autosub 3 during the Pine Island campaign.
机译:在James Cook Cruise 27期间,由于船尾平面执行器的位置反馈电位计发生故障,Autosub6000中止了任务12。 2009年1月前往南极的松岛冰川的Autosub3使用了相同的执行器。Autosub3执行器在冰层下发生类似故障会导致AUV损失。本报告首先介绍了对故障的调查并显示了电位计的导电塑料走线从其陶瓷基板上脱落并破裂的情况。然后,该报告描述了为评估电位计的可靠性而进行的测试。这涉及加速老化测试,以模拟执行器中电位计看到的最坏情况。这是通过以4Hz振荡电位器来模拟执行器的运动,同时使电位器周围的Morlina 10油的压力循环而实现的。执行器中使用的电位计不可用,所以5k?来自相同范围的电位计作为替代品进行了测试。假设这些5k?电位计会产生相似的结果,但是在测试过程中发现5k?电位器轨道不同于10k吗?是否会影响可靠性尚不知道。由于每次测试都需要大量时间,因此仅16 5k?电位计进行了测试。尽管未发生任何故障,但样本太小,无法提供很高的统计可信度,即电位计可以在巡航过程中幸免。进一步降低四个5k的风险? Autosub3上使用的电位计在“预烧”过程中进行了约72小时的测试。由于在此过程中可能会检测到类似于Autosub6000电位计的早期故障,因此大大降低了电位计发生故障的可能性。因此,在Pine Island战役期间,电位计上的烧焦被认为可以在Autosub 3上使用。

著录项

  • 作者

    Furlong M.E.; Brito M.P.;

  • 作者单位
  • 年度 2009
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号