Polarization and Depolarization Current (PDC) technique is an effective tool to assess the condition of oil-paper insulation system in power transformers. So far the PDC behaviors of mineral oil-paper insulation have been widely investigated. However, with the increasing number of transformer choosing natural ester as its insulation oil, it is important to investigate the PDC characteristics of natural ester-paper insulation to see whether the PDC technique can also be used to assess the condition of new insulation system using natural ester in transformers accurately. In this research, natural esterpaper insulation sample and mineral oil-paper insulation sample were subjected to thermally accelerated ageing experiment at 110 °C for 120 days. The PDC characteristics of natural ester-paper insulation sample and mineral oil-paper insulation sample were compared over the ageing process. A new method for assessing the ageing condition of the oil-paper insulation in terms of the depolarization charge quantity was proposed. Results show that the polarization/depolarization current of natural ester-paper insulation sample is higher than that of mineral oil-paper insulation sample with the same ageing intervals. The depolarization charge quantity of both kinds of oil-paper insulation sample is very sensitive to their ageing conditions. There is an exponential relation between the stable depolarization charge quantity of both kinds of oil-paper insulation sample and the degree of polymerization (DP) of paper. The depolarization charge quantity can be used to predict the ageing condition of oil-paper insulation providing the measurement temperature is kept the same.
机译:极化和去极化电流(PDC)技术是评估电力变压器油纸绝缘系统状况的有效工具。到目前为止,已经广泛研究了矿物油纸绝缘材料的PDC行为。但是,随着越来越多的变压器选择天然酯作为绝缘油,研究天然酯-纸绝缘的PDC特性以了解是否也可以将PDC技术用于评估使用天然酯的新型绝缘系统的状况非常重要。准确地在变压器中酯化。在这项研究中,天然酯纸绝缘样品和矿物油纸绝缘样品在110°C下进行了120天的热加速老化实验。比较了天然酯纸绝缘样品和矿物油纸绝缘样品在老化过程中的PDC特性。提出了一种根据去极化电荷量评估油纸绝缘层老化状态的新方法。结果表明,在相同的老化间隔下,天然酯纸绝缘样品的极化/去极化电流要高于矿物油纸绝缘样品的极化/去极化电流。两种油纸绝缘样品的去极化电荷量对它们的老化条件非常敏感。两种油纸绝缘样品的稳定去极化电荷量与纸的聚合度(DP)之间存在指数关系。如果测量温度保持不变,则去极化电荷量可用于预测油纸绝缘的老化条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号