首页> 外文OA文献 >Analysis of current and voltage indicators in grid connected PV (photovoltaic) systems working in faulty and partial shading conditions
【2h】

Analysis of current and voltage indicators in grid connected PV (photovoltaic) systems working in faulty and partial shading conditions

机译:分析在故障和部分遮蔽条件下工作的并网pV(光伏)系统中的电流和电压指示器

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

To ensure the optimization of the energy generated by grid connected PV (photovoltaic) systems is necessary to plan a strategy of automatic fault detection. The analysis of current and voltage indicators have demonstrated effectiveness in the detection of permanent faults in the PV array in real time as short-circuits or open circuits present in the system. In this paper, the analysis of the evolution of these indicators is focused on the detection of temporary faults due to partial shade on the PV array or disconnection of the inverter in case of grid fluctuations of voltage or frequency to prevent islanding. These situations can be identified by observation of the evolution of both indicators and power losses due to these effects can be evaluated from them. The analysis and experimental validation were carried out in two grid connected PV systems in Spain and Algeria.
机译:为了确保优化并网光伏(光伏)系统产生的能量,有必要规划自动故障检测策略。电流和电压指示器的分析已证明有效地实时检测PV阵列中出现短路或开路的永久性故障。在本文中,对这些指标演变的分析重点在于检测由于光伏阵列上的部分阴影或逆变器断开而导致的临时故障,以防止电压或频率出现电网波动以防止孤岛。可以通过观察指标的演变来识别这些情况,并可以从中评估由于这些影响而导致的功率损耗。在西班牙和阿尔及利亚的两个并网光伏系统中进行了分析和实验验证。