首页> 外文OA文献 >Trace ammonium removal by liquid-liquid membrane contactors as water polishing step of water electrolysis for hydrogen production from a wastewater treatment plant effluent
【2h】

Trace ammonium removal by liquid-liquid membrane contactors as water polishing step of water electrolysis for hydrogen production from a wastewater treatment plant effluent

机译:通过液 - 液膜接触器去除痕量铵作为水电解的水抛光步骤,用于从废水处理厂流出物中产生氢气

摘要

© 2016 Society of Chemical Industry. BACKGROUND: This work evaluates hollow fiber liquid-liquid membrane contactors (HFMC) as a polishing step for the removal of low levels of ammonium from water purified by (or being supplied to) a membrane distillation unit in order to fulfil the conductivity requirements of hydrogen production by water electrolysis. RESULTS: The influence of the operating conditions (flow, pH, ammonium concentration, buffer capacity) were evaluated under a closed-loop setup in order to achieve a reduction of total ammonia concentration in water, from 15 to 1mgL-1 to assure the production of water in the membrane distillation with a conductivity lower than 1 µS cm-1. These values were used to validate a numerical algorithm describing the system performance. In order to reach the ammonia concentration requirements and considering the low concentration of bicarbonate (low pH buffer capacity) in the treated water a buffer agent was added to the working solution. CONCLUSIONS: HFMC technology is a suitable solution to remove low levels of ammonium from water to values as low as 1mgL- 1NH3 through appropriate control of pH. The ammonium removal efficiency of the HFMC was improved by raising the pH or the flow rate. Finally, the model proposed provides a good description of the membrane contactor performance with minimal deviations when compared with experimental results.
机译:©2016年化学工业协会。背景:这项工作评估中空纤维液-液膜接触器(HFMC)作为抛光步骤,以从通过膜蒸馏单元纯化(或供应至膜蒸馏单元)中去除水中的少量铵,以满足氢的电导率要求通过水电解生产。结果:在闭环设置下评估了操作条件(流量,pH,铵浓度,缓冲容量)的影响,以实现将水中总氨浓度从15mgL-1降低至1mgL-1,以确保生产膜蒸馏中水的电导率低于1 µS cm-1。这些值用于验证描述系统性能的数值算法。为了达到氨的浓度要求,并考虑到处理后的水中碳酸氢盐的浓度低(pH缓冲液容量低),将缓冲剂添加到工作溶液中。结论:HFMC技术是一种合适的解决方案,可通过适当控制pH值来从水中去除低含量的铵盐,使其浓度低至1mgL-1NH3。通过提高pH或流速可以提高HFMC的除铵效率。最后,与实验结果相比,所提出的模型以最小的偏差很好地描述了膜接触器的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号