首页> 外文OA文献 >Intra-rater reliability and diagnostic accuracy of a new vaginal dynamometer to measure pelvic floor muscle strength in women with urinary incontinence
【2h】

Intra-rater reliability and diagnostic accuracy of a new vaginal dynamometer to measure pelvic floor muscle strength in women with urinary incontinence

机译:新型阴道测力计测量尿失禁女性盆底肌力的评估内可靠性和诊断准确性

摘要

The first choice treatment in urinary incontinence (UI) is rehabilitation of the pelvic floor in order to improve muscle strength. However, no entirely reliable instruments for quantifying pelvic floor muscle (PFM) strength are currently available. Our aim was to test the intra-rater reliability and diagnostic accuracy of a new vaginal dynamometerudfor measuring PFM strength. Methods: Test-retest reliability study. One hundred and four women with stress urinary incontinence (SUI) were recruited. Patients were excluded if they had a history consistent with urge urinary incontinence or pelvic organ prolapse, pregnancy, previous urogynecological surgery, severe vaginal atrophy, or neurological conditions. The examination comprised digital palpation quantified by the modified Oxford scale and by two consecutiveuddynamometry measurements obtained using a new prototype dynamometer. This instrument comprises a speculum inudwhich an inductive displacement sensor (LVDTSM210.10.2.KTmodel, Schreiber) is attached to a spring of known stiffness constant (k). The intraclass correlation coefficient (ICC) was calculated to assess intra-rater reliability.udDiagnostic accuracy was assessed using Receiver Operating Characteristics (ROC) curves analysis. Results: Of the 104 subjects included, 59.6% presented scores between 0–2 on the Oxford scale. Intra-rater reliability was 0.98 (95%CI: 0.97– 0.99). In the Bland & Altman plot, the distribution of disagreements was similar in the lowest and the highest strength values. The diagnostic accuracy of the dynamometer with regard to digital palpation showed an area under the curve of 0.85 (95%CI: 0.77–0.93). Conclusions: Our results suggest that this new vaginal dynamometer is a reliable and validudinstrument for quantifying PFM strength.
机译:尿失禁(UI)的首选治疗方法是恢复骨盆底,以提高肌肉强度。但是,目前尚无用于量化骨盆底肌肉(PFM)强度的完全可靠的仪器。我们的目的是测试用于测量PFM强度的新型阴道测力计 ud的评定者内可靠性和诊断准确性。方法:重测可靠性研究。招募了104名患有压力性尿失禁(SUI)的妇女。如果患者的病史与急迫性尿失禁或盆腔器官脱垂,怀孕,以前的泌尿妇科手术,严重的阴道萎缩或神经系统疾病一致,则将其排除。该检查包括通过改良的牛津秤和通过使用新的原型测功机获得的两次连续测功法测量来量化的数字触诊。该仪器包括一个窥器,其中一个感应位移传感器(LVDTSM210.10.2.KTmodel,Schreiber)连接到已知刚度常数(k)的弹簧上。计算组内相关系数(ICC)以评估评定者内部可靠性。 ud使用接收器工作特征(ROC)曲线分析评估诊断准确性。结果:纳入的104名受试者中,有59.6%的人在牛津量表上的得分在0-2之间。评分者内部可靠性为0.98(95%CI:0.97-0.99)。在Bland&Altman图中,在最低强度值和最高强度值中,分歧的分布相似。测力计对数字触诊的诊断准确性显示曲线下面积为0.85(95%CI:0.77-0.93)。结论:我们的结果表明,这种新型的阴道测力计是定量PFM强度的可靠且有效的仪器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号