首页> 外文OA文献 >A Dual-Readout F2 Assay That Combines Fluorescence Resonance Energy Transfer and Fluorescence Polarization for Monitoring Bimolecular Interactions
【2h】

A Dual-Readout F2 Assay That Combines Fluorescence Resonance Energy Transfer and Fluorescence Polarization for Monitoring Bimolecular Interactions

机译:双读数F2测定结合荧光共振能量转移和荧光偏振监测双分子相互作用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Forster (fluorescence) resonance energy transfer (FRET) and fluorescence polarization (FP) are widely used technologies for monitoring bimolecular interactions and have been extensively used in high-throughput screening (HTS) for probe and drug discovery. Despite their popularity in HTS, it has been recognized that different assay technologies may generate different hit lists for the same biochemical interaction. Due to the high cost of large-scale HTS campaigns, one has to make a critical choice to employee one assay platform for a particular HTS. Here we report the design and development of a dual-readout HTS assay that combines two assay technologies into one system using the Mcl-1 and Noxa BH3 peptide interaction as a model system. In this system, both FP and FRET signals were simultaneously monitored from one reaction, which is termed -Dual-Readout F2 assay- with F2 for FP and FRET. This dual-readout technology has been optimized in a 1,536-well ultra-HTS format for the discovery of Mcl-1 protein inhibitors and achieved a robust performance. This F2 assay was further validated by screening a library of 102,255 compounds. As two assay platforms are utilized for the same target simultaneously, hit information is enriched without increasing the screening cost. This strategy can be generally extended to other FP-based assays and is expected to enrich primary HTS information and enhance the hit quality of HTS campaigns.
机译:Forster(荧光)共振能量转移(FRET)和荧光偏振(FP)是监视双分子相互作用的广泛使用的技术,并已广泛用于探针和药物发现的高通量筛选(HTS)。尽管它们在HTS中很受欢迎,但是已经认识到,不同的测定技术可能为相同的生化相互作用生成不同的命中列表。由于大规模HTS活动的成本高昂,因此必须为员工做出一项关键选择,即针对特定HTS的一种检测平台。在这里,我们报告设计和开发的双重读出的HTS分析,将Mcl-1和Noxa BH3肽相互作用作为模型系统,将两种分析技术结合到一个系统中。在该系统中,从一个反应中同时监视FP和FRET信号,这被称为-FP和FRET的F2双读数F2分析。这项双重读出技术已针对1,536孔超HTS格式进行了优化,以发现Mcl-1蛋白抑制剂,并实现了强大的性能。通过筛选102,255种化合物的文库进一步验证了该F2分析的有效性。由于两个测定平台同时用于同一靶标,因此丰富了命中信息,而又不增加筛选成本。此策略通常可以扩展到其他基于FP的分析,并且有望丰富主要的HTS信息并提高HTS活动的命中质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号