Using GafChromic film to estimate the effective dose from dental cone beam CT and panoramic radiography

机译:使用GafChromic薄膜估算牙科锥形束CT和全景摄影的有效剂量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

Objectives: To demonstrate the feasibility of GafChromic(®) XR-QA2 (ISP Corp., Wayne, NJ) as a dosemeter when performing measurements of the effective dose from three cone beam CT (CBCT) units and to compare the doses from examinations of three common dental clinical situations. A second aim was to compare the radiation doses for three digital panoramic units with the doses for the CBCT units.METHODS:The CBCT units used were Veraviewepocs 3De(®) (J Morita MFG Corp., Kyoto, Japan), ProMax(®) 3D (Planmeca, Helsinki, Finland) and NewTom VGi(®) (Quantitative Radiology, Verona, Italy). GafChromic XR-QA2 films were placed between the selected layers of the head and neck of a tissue-equivalent human skull (RANDO(®) phantom; The Phantom Laboratory, Salem, NY). The exposure parameters were set using the automatic exposure control function of the units. Depending on the availability, medium and smaller field of view (FOV) scanning modes were used. The effective dose was estimated using the 2007 International Commission on Radiological Protection formalism.RESULTS:The lowest effective dose of a CBCT unit was observed for ProMax 3D, FOV 4 × 5 cm (10 μSv), the highest for NewTom VGi, FOV 8 × 8 cm-high resolution (129 μSv). The range of effective doses for digital panoramic machines measured was 8-14 μSv.CONCLUSIONS:This study demonstrates the feasibility of using radiochromic films for dental CBCT and panoramic dosimetry.
机译:目的:演示在对三个锥形束CT(CBCT)单元进行有效剂量测量时,GafChromic(R)XR-QA2(ISP Corp.,Wayne,NJ)作为剂量计的可行性,并比较检查三种常见的牙科临床情况。第二个目的是将三个数字全景单元的辐射剂量与CBCT单元的辐射剂量进行比较。方法:所使用的CBCT单元是Veraviewepocs 3De(®)(J Morita MFG Corp.,Kyoto,日本)和ProMax(®)。 3D(芬兰赫尔辛基的普兰梅卡)和NewTomVGi®(意大利维罗纳的定量放射学)。将GafChromic XR-QA2膜放置在组织等效的人类头骨(幻影;幻影实验室,纽约州塞勒姆)的头部和颈部的选定层之间。使用单元的自动曝光控制功能设置曝光参数。根据可用性,使用了中小型视野(FOV)扫描模式。结果:使用ProMax 3D,FOV 4×5 cm(10μSv)观察到CBCT单位的最低有效剂量,使用NewTom VGi,FOV 8OV×观察到CBCT单位的最低有效剂量。高分辨率(8 cm)(129 Sv)。数字全景机的有效剂量范围为8-14μSv。结论:本研究证明了使用放射致变色胶片进行牙科CBCT和全景剂量测定的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号