首页> 外文OA文献 >Experimental evaluation of HCFO-1233zd-E as HFC-245fa replacement in an Organic Rankine Cycle system for low temperature heat sources
【2h】

Experimental evaluation of HCFO-1233zd-E as HFC-245fa replacement in an Organic Rankine Cycle system for low temperature heat sources

机译:HCFO-1233zd-E作为低温热源有机朗肯循环系统中HFC-245fa替代物的实验评价

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In this work an experimental evaluation of the working fluid HCFO-1233zd-E as HFC-245fa replacement in ORC systems for low temperature heat sources has been conducted. A fully monitored ORC module has been used to test both working fluids at different operating conditions. Due to the different densities of the working fluids, the mass flow rate for HCFO-1233zd-E is approximately 20% lower than for HFC-245fa. This causes thermal and electrical powers to be lower for HCFO-1233zd-E than for HFC-245fa. However, net electrical efficiency is similar for both working fluids, ranging from 5% to 9.7% in the tested operating conditions. Regarding the expander performance, various performance indicators are addressed. The expander isentropic performance has a maximum value of 75%, with higher values for HCFO-1233zd-E than for HFC-245fa. The overall efficiency of the expander, similar for both working fluids, ranges from 44% to 57% in the experimental test range.
机译:在这项工作中,对低温热源ORC系统中作为HFC-245fa替代品的工作液HCFO-1233zd-E进行了实验评估。完全监控的ORC模块已用于测试不同工作条件下的两种工作流体。由于工作流体的密度不同,HCFO-1233zd-E的质量流率比HFC-245fa低约20%。这导致HCFO-1233zd-E的热和电功率低于HFC-245fa。但是,两种工作流体的净电效率相似,在测试的工作条件下范围为5%至9.7%。关于扩展器性能,解决了各种性能指标。膨胀机的等熵性能最大值为75%,HCFO-1233zd-E的值高于HFC-245fa。膨胀剂的总效率(在两种工作流体中相似)在实验测试范围内为44%至57%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号