The use of a new atmospheric-pressure chemical ionization source for gas chromatography (APGC) coupled with a tandem quadrupole mass spectrometry (MS/MS) system, as an alternative to high-resolution mass spectrometry (HRMS), for the determination of PCDDs/PCDFs is described.The potential of using atmospheric-pressure chemical ionization (APCI) coupled to a tandem quadrupole analyzer has been validated for the identification and quantification of dioxins and furans in different complexmatrices. The main advantage of using the APCI source is the soft ionization atatmospheric pressure, which results in very limited fragmentation. APCI mass spectra are dominated by the molecular ion cluster, in contrast with the high energy ionization process under electron ionization (EI). The use of themolecular ion as the precursor ion in MS/MS enhances selectivity and, consequently, sensitivity by increasing the signal-to-noise ratios (S/N). For standard solutions of 2,3,7,8-TCDD, injections of 10 fg in the splitless mode on 30- or 60-m-length, 0.25 mm inner diameter (id), and 25 μ m film thickness low-polarity capillary columns (DB5MS type),signal-to-noise (S/N) ratios of >10:1 were routinely obtained. Linearity was achieved in the region (correlation coefficient of r2 > 0.998) for calibration curves ranging from 100 fg/μ L to 1000 pg/ μ L. The results from a wide variety of complex samples, including certified and standard reference materials and samples from several QA/QC studies, which were previously analyzed by EI HRGC/HRMS, were compared with the results from the APGC/MS/MS system. Results between instruments showed good agreement both in individual congeners and toxic equivalence factors (TEQs). The data show that the use of APGC in combination with MS/MS for the analysis of dioxins has the same potential, in terms of sensitivity and selectivity, as the traditional HRMS instrumentation used for this analysis. However, the APCI/MS/MS system, as a benchtop system, is much easier to use.
机译:使用新型常压化学电离源进行气相色谱分析(APGC)和串联四极杆质谱分析(MS / MS)系统,作为高分辨率质谱分析法(HRMS)的替代方法,用于测定PCDDs /描述了PCDFs。已验证使用大气压化学电离(APCI)串联四极杆分析仪的潜力,可用于鉴定和定量不同络合物中的二恶英和呋喃。使用APCI离子源的主要优点是在大气压力下产生软电离,这导致碎片非常有限。与电子电离(EI)下的高能电离过程相反,APCI质谱以分子离子簇为主导。在MS / MS中使用分子离子作为前体离子可提高信噪比(S / N),从而提高选择性,从而提高灵敏度。对于2,3,7,8-TCDD的标准溶液,在30或60 m长度,0.25 mm内径(id)和25μm膜厚的低极性毛细管上以不分流方式进样10 fg常规获得色谱柱(DB5MS型),信噪比(S / N)> 10:1。在100 fg /μL至1000 pg /μL的校准曲线的区域内(相关系数r2> 0.998)实现了线性。多种复杂样品的结果,包括认证的和标准的参考材料以及来自先前由EI HRGC / HRMS分析过的一些QA / QC研究与APGC / MS / MS系统的结果进行了比较。仪器之间的结果在单个同源物和毒性当量因子(TEQ)方面均显示出良好的一致性。数据表明,在灵敏度和选择性方面,结合使用APGC和MS / MS进行二恶英的分析与用于此分析的传统HRMS仪器具有相同的潜力。但是,作为台式系统的APCI / MS / MS系统更易于使用。

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号