Slender double-tube ultra-high strength concrete-filled tubular columns under ambient temperature and fire

机译:在环境温度和火灾下细长的双管超高强度混凝土管柱

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This paper presents the results of an experimental campaign where both the room temperature and the fire resistance of six double-tube concrete filled steel tubular slender columns with different combinations of concrete strength are studied. Firstly, the ultimate axial load of the specimens at room temperature was experimentally obtained and afterwards the fire resistance of such columns subjected to a 20% of their load bearing capacity was measured. Given the reduced number of experimental results found in the literature on slender concrete filled tubular columns with double steel tubular cross-sections, the main objective of this paper is to compare the behaviour of such innovative cross-sections under ambient and high temperatures. The influence of filling the inner ring with concrete on the fire performance of these columns is studied in this paper, as well as the variation of thicknesses of the outer and inner steel tubes. Despite the fact that the tested columns are not covered by the scope of Eurocode 4, the current simple calculation models were applied in this paper in order to assess the validity of the standard to this typology of columns, unsafe results being found.
机译:本文介绍了一项实验研究的结果,其中研究了六种不同混凝土强度组合的双管钢管混凝土细长柱的室温和耐火性。首先,通过实验获得样品在室温下的极限轴向载荷,然后测量承受这种柱的20%承载力的耐火性。考虑到文献中关于带有双钢管横截面的细长混凝土填充管柱的实验结果数量减少,本文的主要目的是比较这种创新横截面在环境和高温下的性能。本文研究了用混凝土填充内圈对这些柱的防火性能的影响,以及内外钢管厚度的变化。尽管被测试的色谱柱不在欧洲规范4的范围之内,但本文还是采用了当前的简单计算模型,以便评估该色谱柱类型标准的有效性,发现了不安全的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号