首页> 外文OA文献 >Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage vapour compression plant
【2h】

Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage vapour compression plant

机译:R404a和R507a制冷剂混合物在实验性双级蒸汽压缩装置中的性能评价

摘要

As a result of the ban of the CFC fluids in 2000 and the future limitation of HCFC fluids, which manufacture limit is the year 2010, refrigerant producers have been working to develop different mixtures, mainly based on HFC fluids, which emulate the properties of the former refrigerants used in refrigeration plants. At the moment, the HFC-404A and the HFC-507A are the more widely used fluids in Europe as replacement of the CFC-502 in plants operating at low temperatures. This work presents the experimental evaluation, from an energy point of view, of both refrigerants in the same refrigeration plant, which corresponds to a double-stage vapour compression plant driven by a compound compressor. The characterization was made for an evaporating temperature range between −36 and −20 °C for a constant condensing temperature of 40 °C.
机译:由于2000年禁止使用CFC液体以及HCFC液体的未来限制(制造限制是2010年),制冷剂生产商一直在努力开发主要基于HFC液体的不同混合物,这些混合物模仿了HFC液体的特性。用于制冷厂的前制冷剂。目前,HFC-404A和HFC-507A是欧洲使用最广泛的流体,以代替在低温下运行的工厂中的CFC-502。这项工作从能源的角度提出了对同一制冷设备中的两种制冷剂的实验评估,这相当于由复合压缩机驱动的双级蒸汽压缩设备。对于−36至-20°C的蒸发温度范围和恒定的40°C冷凝温度进行了表征。