首页> 外文OA文献 >Determination of free amino acids in plants by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)
【2h】

Determination of free amino acids in plants by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)

机译:液相色谱 - 串联质谱联用(LC-ms / ms)测定植物体内游离氨基酸

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A robust and sensitive method for identification (quantification and confirmation) of 19 free amino acids in the plant matrix, Stellaria media, based on liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS), with a triple quadrupole analyser, has been developed. Regarding MS optimization, flow injection analysis (FIA) was used in scan and selected reaction monitoring (SRM) mode. The collision energies optimized varied from −12 to −39 eV. The acquisition of three MS/MS transitions for most of the compounds allowed the accurate confirmation of these analytes, which was supported by the accomplishment of ion intensity ratios and retention time as compared with the corresponding standards. The use of a Phenomenex EZ:faast™ Free (Physiological) Amino Acid kit speeds up the sample preparation immeasurably. Nineteen amino acids were separated within 18 minutes on a reverse-phase column under a gradient stepwise programme using 10 mM ammonium formate both in water and methanol. The detection limit (LOD) for free amino acids varied from 0.4 to 9.1 pmol mL−1, except for asparagine amounting to 3000 pmol mL−1. The quantification precision (RSD) of free amino acids for intra- and interday assays was 0.05–19% and 0.2–19%, respectively, but for most of the compounds, it did not exceed 5%. The optimized and validated method was subsequently utilized for free amino acid identification in weed collected from field locations in Poland.
机译:基于液相色谱-电喷雾串联质谱(LC-ESI-MS / MS)的三重四极杆质谱法,用于鉴定(定量和确认)植物基质(恒星培养基)中19种游离氨基酸的可靠而灵敏的方法分析仪,已开发。关于质谱优化,流动注射分析(FIA)用于扫描和选定的反应监测(SRM)模式。优化的碰撞能量在-12至-39 eV之间变化。对于大多数化合物,通过三个MS / MS离子对的转换,可以对这些分析物进行准确确认,与相应标准品相比,离子强度比和保留时间的实现为该方法提供了支持。使用Phenomenex EZ:faast™Free(生理学)氨基酸试剂盒可无可估量地加快样品制备速度。在反相色谱柱上,在梯度逐步程序下,使用10 mM甲酸铵的水溶液和甲醇溶液,在18分钟内分离出19个氨基酸。游离氨基酸的检出限(LOD)在0.4至9.1 pmol mL-1之间,除了天冬酰胺的含量为3000 pmol mL-1。日内和日间检测的游离氨基酸定量精度(RSD)分别为0.05–19%和0.2–19%,但对于大多数化合物,其不超过5%。经过优化和验证的方法随后用于从波兰田间地点收集的杂草中游离氨基酸的鉴定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号