首页> 外文OA文献 >Variability in skin prick test results performed by multiple operators depends on the device used.
【2h】

Variability in skin prick test results performed by multiple operators depends on the device used.

机译:由多个操作员执行的皮肤点刺测试结果的可变性取决于所使用的设备。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

BACKGROUND: : The variability of skin prick test results when carried out by multiple users has not previously been assessed across different devices or between different sites on the body. Such multiuser variability has important implications for clinical practice. OBJECTIVES: : We assessed the variability of measurements from 4 commonly used single-headed skin test devices when used by multiple operators and examined whether the variability in performance was different on the back compared with the forearm. METHODS: : Eight adult volunteer "operators" were trained in the use of 4 devices: Greer Pick, Quintip, Stallergenes Lancet, and Feather Lancet. Each operator performed a histamine skin prick test with all devices on the backs and forearms of 5 volunteer "receivers." Variability in results was assessed using a multilevel (random effects) regression model. RESULTS: : After controlling for variation between users and receivers, the residual variability or "measurement error" was least for the Stallergenes Lancet, closely followed by the Quintip. The Greer Pick had the greatest variability. There was greater variability in measurements on the arm compared with the back. CONCLUSIONS: : The devices using the "puncture" method (Stallergenes Lancet, Quintip) provide less variability in results than those using a "prick" method when carried out by multiple users (Greer Pick and Feather Lancet). Testing on the back also gives less variable results compared with the arm.
机译:背景:多个用户进行的皮肤点刺测试结果的变异性以前尚未在不同设备之间或身体不同部位之间进行评估。这种多用户差异性对临床实践具有重要意义。目的::我们评估了由多个操作员使用时,从4种常用的单头皮肤测试设备获得的测量结果的变异性,并检查了与前臂相比,背部的表现变异性是否不同。方法:对八名成人志愿者“操作员”进行了4种设备的使用方面的培训:格里尔·皮克(Greer Pick),昆蒂普(Quintip),史泰尔盖格尼斯·柳叶刀(Stallergenes Lancet)和羽毛柳叶刀。每个操作员在5名志愿者“接收者”的背部和前臂的所有器械上进行组胺皮肤点刺试验。使用多级(随机效应)回归模型评估结果的变异性。结果:在控制了用户和接收者之间的差异之后,Stallergenes Lancet的剩余变异性或“测量误差”最小,紧随其后的是Quintip。 Greer Pick的可变性最大。与背部相比,手臂的测量值存在较大差异。结论:与多个用户(Greer Pick和Feather Lancet)一起使用“穿刺”方法的设备(Stallergenes Lancet,Quintip)相比,使用“穿刺”方法的设备提供的结果变化更少。与手臂相比,在背部进行测试还可以减少可变的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号