首页> 外文OA文献 >The effect of blood inflow and B1-field inhomogeneity on measurement of the arterial input function in axial 3D spoiled gradient echo dynamic contrast-enhanced MRI
【2h】

The effect of blood inflow and B1-field inhomogeneity on measurement of the arterial input function in axial 3D spoiled gradient echo dynamic contrast-enhanced MRI

机译:血流量和B1场不均匀性对轴位三维损伤梯度回波动态增强mRI动脉输入功能测量的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

A major potential confound in axial 3D dynamic contrast-enhanced magnetic resonance imaging studies is the blood inflow effect; therefore, the choice of slice location for arterial input function measurement within the imaging volume must be considered carefully. The objective of this study was to use computer simulations, flow phantom, and in vivo studies to describe and understand the effect of blood inflow on the measurement of the arterial input function. All experiments were done at 1.5 T using a typical 3D dynamic contrast-enhanced magnetic resonance imaging sequence, and arterial input functions were extracted for each slice in the imaging volume. We simulated a set of arterial input functions based on the same imaging parameters and accounted for blood inflow and radiofrequency field inhomogeneities. Measured arterial input functions along the vessel length from both in vivo and the flow phantom agreed with simulated arterial input functions and show large overestimations in the arterial input function in the first 30 mm of the vessel, whereas arterial input functions measured more centrally achieve accurate contrast agent concentrations. Use of inflow-affected arterial input functions in tracer kinetic modeling shows potential errors of up to 80% in tissue microvascular parameters. These errors emphasize the importance of careful placement of the arterial input function definition location to avoid the effects of blood inflow.
机译:轴向3D动态对比增强磁共振成像研究的主要潜在困惑是血液流入效应。因此,必须仔细考虑在成像体积内选择用于动脉输入功能测量的切片位置。这项研究的目的是使用计算机模拟,体模和体内研究来描述和理解血液流入对动脉输入功能的测量的影响。使用典型的3D动态对比增强磁共振成像序列在1.5 T下完成所有实验,并为成像体积中的每个切片提取了动脉输入功能。我们基于相同的成像参数模拟了一组动脉输入功能,并考虑了血液流入量和射频场的不均匀性。从体内和体模沿着血管长度测量的动脉输入功能与模拟的动脉输入功能一致,并且在血管的前30 mm处显示出对动脉输入功能的高估,而更集中地测量的动脉输入功能可实现准确的对比度药剂浓度。在示踪剂动力学建模中使用受流入影响的动脉输入功能显示组织微血管参数中的潜在误差高达80%。这些错误强调了小心放置动脉输入功能定义位置以避免血液流入的影响的重要性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号